Suppr超能文献

滤波单极电图形态在评估肺静脉隔离术中消融灶透壁性方面的应用价值。

Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation.

作者信息

Kogawa Rikitake, Watanabe Ichiro, Okumura Yasuo, Mano Hiroaki, Sonoda Kazumasa, Nagashima Koichi, Sasaki Naoko, Ohkubo Kimie, Takahashi Keiko, Iso Kazuki, Kurokawa Sayaka, Nakai Toshiko, Hirayama Atsushi

机构信息

Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Oyaguchi-kami, Itabashi-ku, Tokyo 173-8610, Japan.

出版信息

J Arrhythm. 2016 Apr;32(2):108-11. doi: 10.1016/j.joa.2015.10.001. Epub 2015 Nov 27.

Abstract

BACKGROUND

Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms. The amplitude and morphology of filtered bipolar (BP) and filtered unipolar (UP) electrograms were compared during pulmonary vein isolation in patients with atrial fibrillation.

METHODS

BP (30-250 Hz) and UP (30-100 Hz) signals from the ablation catheter were recorded before and after each ablation point at the pulmonary vein antrum in 6 patients with atrial fibrillation.

RESULTS

In the electrogram group with low-voltage amplitude in BP electrograms before ablation (<0.5 mV), the reduction in amplitude after ablation was significantly greater in the UP than in the BP electrograms, whereas the reduction was similar between the two recording methods in the electrogram group with high-voltage amplitude in BP electrograms (≥0.5 mV). Furthermore, the S wave in the UP electrograms disappeared at the sites of no pace capture after ablation, whereas no characteristic morphologic changes were observed in the BP electrograms.

CONCLUSION

Filtered UP electrograms may be useful in assessing the effectiveness of lesion formation.

摘要

背景

尽管双极电图的振幅和形态改变被广泛用作消融效果的指导,但关于单极电图的信息却很少。在心房颤动患者的肺静脉隔离过程中,对滤波后的双极(BP)和滤波后的单极(UP)电图的振幅和形态进行了比较。

方法

记录6例心房颤动患者在肺静脉窦每个消融点前后消融导管的BP(30 - 250Hz)和UP(30 - 100Hz)信号。

结果

在消融前BP电图电压振幅低(<0.5mV)的电图组中,消融后UP电图的振幅降低明显大于BP电图,而在BP电图电压振幅高(≥0.5mV)的电图组中,两种记录方法的降低幅度相似。此外,消融后无夺获部位的UP电图中的S波消失,而BP电图未观察到特征性形态学改变。

结论

滤波后的UP电图可能有助于评估损伤形成的有效性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4bc4/4823572/c42e815b54d6/gr1.jpg

相似文献

10
Comparison of bipolar and unipolar radiofrequency ablation in an in vivo experimental model.体内实验模型中双极与单极射频消融的比较。
Eur J Cardiothorac Surg. 2005 Jul;28(1):76-80; discussion 80-2. doi: 10.1016/j.ejcts.2005.02.028. Epub 2005 Apr 7.

本文引用的文献

8
Simultaneous creation and evaluation of linear radiofrequency lesions.
J Interv Card Electrophysiol. 2002 Jul;6(3):215-24. doi: 10.1023/a:1019553619013.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验