减少光电容积脉搏波描记术中的周期性运动伪影。

Reduction of Periodic Motion Artifacts in Photoplethysmography.

作者信息

Wijshoff Ralph W C G R, Mischi Massimo, Aarts Ronald M

出版信息

IEEE Trans Biomed Eng. 2017 Jan;64(1):196-207. doi: 10.1109/TBME.2016.2553060. Epub 2016 Apr 12.

Abstract

UNLABELLED

Periodic motion artifacts affect photoplethysmography (PPG) signals in activities of daily living (ADL), cardiopulmonary exercise testing (CPX), and cardiopulmonary resuscitation (CPR). This hampers measurement of interbeat intervals (IBIs) and oxygen saturation (SpO ). Our objective was to develop a generic algorithm to remove periodic motion artifacts, recovering artifact-reduced PPG signals for beat-to-beat analysis.

METHODS

The algorithm was retrospectively evaluated on forehead PPG signals measured while walking on a treadmill. The step rate was tracked in a motion reference signal via a second-order generalized integrator with a frequency-locked loop. Two reference signals were compared: sensor motion relative to the skin ( ∆x[n]) measured via self-mixing interferometry and head motion ( a[n] ) measured via accelerometry. The step rate was used in a quadrature harmonic model to estimate the artifacts. Quadrature components need only two coefficients per frequency leading to a short filter and prevent undesired frequency-shifted components in the artifact estimate. Subtracting the estimate from the measured signal reduced the artifacts.

RESULTS

Compared to ∆x[n] , a[n] had a better signal-to-noise ratio and more consistently contained a component at the step rate. Artifact reduction was effective for distinct step rate and pulse rate, since the artifact-reduced signals provided more stable IBI and SpO measurements.

CONCLUSION

Accelerometry provided a more reliable motion reference signal. The proposed algorithm can be of significance for monitoring in ADL, CPX, or CPR, by providing artifact-reduced PPG signals for improved IBI and SpO measurements during periodic motion.

摘要

未标注

周期性运动伪影会影响日常生活活动(ADL)、心肺运动试验(CPX)和心肺复苏(CPR)中的光电容积脉搏波描记法(PPG)信号。这妨碍了心跳间期(IBI)和血氧饱和度(SpO₂)的测量。我们的目标是开发一种通用算法来去除周期性运动伪影,恢复用于逐搏分析的减少伪影的PPG信号。

方法

该算法在跑步机上行走时测量的前额PPG信号上进行回顾性评估。通过带有锁频环的二阶广义积分器在运动参考信号中跟踪步频。比较了两个参考信号:通过自混合干涉测量法测量的传感器相对于皮肤的运动(∆x[n])和通过加速度测量法测量的头部运动(a[n])。步频用于正交谐波模型来估计伪影。正交分量每个频率仅需要两个系数,从而得到一个短滤波器,并防止伪影估计中出现不需要的频移分量。从测量信号中减去估计值可减少伪影。

结果

与∆x[n]相比,a[n]具有更好的信噪比,并且更一致地包含步频处的一个分量。由于减少伪影后的信号提供了更稳定的IBI和SpO₂测量值,因此伪影减少对于不同的步频和脉搏率是有效的。

结论

加速度测量法提供了更可靠的运动参考信号。所提出的算法对于ADL、CPX或CPR中的监测具有重要意义,通过提供减少伪影的PPG信号来改善周期性运动期间的IBI和SpO₂测量。