Suppr超能文献

介入心脏病学家海马体剂量研究及其对剂量监测的意义

STUDY OF DOSES TO HIPPOCAMPUS OF INTERVENTIONAL CARDIOLOGISTS AND THEIR IMPLICATION FOR DOSIMETRIC MONITORING.

作者信息

Chumak V, Morgun A, Bakhanova E, Voloskyi V

机构信息

National Research Centre for Radiation Medicine, NAMS Ukraine, Melnikova 53, 04050 Kyiv, Ukraine Radiation Protection Institute ATS Ukraine, Melnikova 53, 04050 Kyiv, Ukraine

Radiation Protection Institute ATS Ukraine, Melnikova 53, 04050 Kyiv, Ukraine.

出版信息

Radiat Prot Dosimetry. 2016 Sep;170(1-4):382-6. doi: 10.1093/rpd/ncw091. Epub 2016 Apr 21.

Abstract

Dosimetric monitoring and protection of the personnel involved into interventional procedures is one of the key issues nowadays, yet doses received by their brains were left without rigorous consideration so far. The paper is the fast track of the results of the pilot study of possible magnitude of operator's doses with particular focus on difference between doses in left and right hippocampi and their relation to effective doses of personnel using protective aprons. Monte Carlo simulation of irradiation in a typical interventional cardiology (IC) operation room shows that for standard C-arm angulations difference in doses between left and right hippocampi can be as large as 5-fold (depending on energy and projection), under certain conditions dose to left (most exposed) hippocampus can be up to two times higher than effective dose estimated by a common double dosimetry algorithm. This finding calls for closer attention to possible manifestations of health detriment associated with occupational irradiation of left hippocampus in course of IC practice.

摘要

对介入操作相关人员的剂量监测与防护是当下的关键问题之一,但迄今为止,他们大脑所接受的剂量尚未得到严格考量。本文是一项初步研究结果的快速报告,该研究重点关注操作员剂量的可能量级,特别是左右海马体剂量的差异及其与使用防护围裙人员有效剂量的关系。在典型的介入心脏病学(IC)手术室进行的蒙特卡罗辐射模拟表明,对于标准的C形臂角度,左右海马体之间的剂量差异可能高达5倍(取决于能量和投影方向),在某些情况下,左侧(最易暴露)海马体所接受的剂量可能比普通双剂量算法估算的有效剂量高出两倍。这一发现要求在IC操作过程中,更加密切关注与左侧海马体职业辐射相关的健康损害可能表现。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验