Patil Rupali, Kadam Pankaj, Oswal Chetan, Patil Seema, Jajoo Shweta, Gachake Arati
Department of Prosthodontics, Bharati Vidyapeeth Dental College, Pune, Maharashtra, India.
Department of Prosthodontics Private Practitioners, Pune, Maharashtra, India.
J Int Soc Prev Community Dent. 2016 Mar-Apr;6(2):142-8. doi: 10.4103/2231-0762.178747.
This study evaluated and compared two impression techniques in terms of their dimensional accuracies to reproduce implant positions on working casts.
A master model was designed to simulate a clinical situation. Impressions were made using four techniques: (1) Stock open tray (SOT) technique; (2) stock closed tray (SCT) technique; (3) custom open tray (COT) technique; and (3) custom closed tray (CCT) technique. Reference points on the hexagonal silhouette of the implant on master model and onto the analogs of the obtained master casts were compared after using the four impression techniques. Measurements were made using an optical microscope, capable of recording under 50x magnifications. The means and standard deviations of all the groups and subgroups were calculated and statically analyzed using analysis of variance (ANOVA) and Tukey's test.
The open tray impressions showed significantly less variation from the master model and all the techniques studied were comparable.
All the techniques studied shown some distortion. COT showed the most accurate results of all the techniques.
本研究评估并比较了两种印模技术在工作模型上再现种植体位置的尺寸精度。
设计一个主模型以模拟临床情况。使用四种技术制取印模:(1)成品开放式托盘(SOT)技术;(2)成品封闭式托盘(SCT)技术;(3)定制开放式托盘(COT)技术;以及(3)定制封闭式托盘(CCT)技术。在使用这四种印模技术后,比较主模型上种植体六边形轮廓的参考点与所获得主模型的代型上的参考点。使用能够在50倍放大倍数下记录的光学显微镜进行测量。计算所有组和亚组的均值和标准差,并使用方差分析(ANOVA)和Tukey检验进行统计学分析。
开放式托盘印模与主模型相比显示出显著更小的差异,并且所研究的所有技术具有可比性。
所研究的所有技术均显示出一定程度的变形。COT在所有技术中显示出最准确的结果。