Suppr超能文献

基于偏振敏感光学相干断层扫描技术对滤过泡功能的客观评估

Objective Evaluation of Functionality of Filtering Bleb Based on Polarization-Sensitive Optical Coherence Tomography.

作者信息

Kasaragod Deepa, Fukuda Shinichi, Ueno Yuta, Hoshi Sujin, Oshika Tetsuro, Yasuno Yoshiaki

机构信息

Computational Optics Group University of Tsukuba, Tsukuba, Japan.

Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan.

出版信息

Invest Ophthalmol Vis Sci. 2016 Apr 1;57(4):2305-10. doi: 10.1167/iovs.15-18178.

Abstract

PURPOSE

The fibrosis score is a new diagnostic score that we have developed to evaluate the function of bleb structures after glaucoma filtration surgery using polarization-sensitive optical coherence tomography (PS-OCT). This study aims to assess the efficacy of the fibrosis score in discriminating nonfunctional from the functional blebs.

METHODS

A total of 20 patients who had undergone glaucoma filtration surgery were imaged at different time periods after surgery using PS-OCT. Birefringence tomography of blebs was obtained from PS-OCT, and the fibrosis score was computed for each patient. The fibrosis score is defined as the area of occupation of high birefringence area in the conjunctiva. The blebs were classified as functional or nonfunctional according to the IOP and the application of medication. The power of the fibrosis score to discriminate nonfunctional blebs from functional blebs was evaluated.

RESULTS

The difference in the mean fibrosis score between the functional and nonfunctional bleb group was statistically significant. The fibrosis score showed good ability to discriminate nonfunctional from functional blebs. The area under the receiver operating characteristic curve was 0.82. The best combination of the sensitivity and specificity was 67% and 100%, respectively, for classifying nonfunctional cases.

CONCLUSIONS

The fibrosis score showed a high ability to discriminate nonfunctional from functional blebs. Polarization-sensitive OCT is a noninvasive technique that provides not only the fibrosis score but also standard structural tomography. It can be a comprehensive tool for longitudinal evaluation after filtration surgery for glaucoma.

摘要

目的

纤维化评分是我们开发的一种新的诊断评分,用于使用偏振敏感光学相干断层扫描(PS - OCT)评估青光眼滤过术后泡状结构的功能。本研究旨在评估纤维化评分在区分无功能泡状结构和有功能泡状结构方面的有效性。

方法

共有20例接受青光眼滤过手术的患者在术后不同时间段接受PS - OCT成像。从PS - OCT获得泡状结构的双折射断层扫描,并计算每位患者的纤维化评分。纤维化评分定义为结膜中高双折射区域的占据面积。根据眼压和药物应用情况将泡状结构分为有功能或无功能。评估纤维化评分区分无功能泡状结构和有功能泡状结构的能力。

结果

有功能泡状结构组和无功能泡状结构组的平均纤维化评分差异具有统计学意义。纤维化评分显示出良好的区分无功能泡状结构和有功能泡状结构的能力。受试者工作特征曲线下面积为0.82。对于无功能病例分类,敏感性和特异性的最佳组合分别为67%和100%。

结论

纤维化评分显示出较高的区分无功能泡状结构和有功能泡状结构的能力。偏振敏感OCT是一种无创技术,不仅能提供纤维化评分,还能提供标准的结构断层扫描。它可以成为青光眼滤过术后纵向评估的综合工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验