Sapkota Kishor, Franco Sandra, Sampaio Paula, Lira Madalena
Centre of Physics, University of Minho, Braga, Portugal.
Centre of Molecular and Environmental Biology (CBMA), University of Minho, Braga, Portugal.
Clin Exp Optom. 2016 Jul;99(4):336-41. doi: 10.1111/cxo.12373. Epub 2016 May 5.
The purpose of this study was to investigate the effect of three months of soft contact lens wear on conjunctival goblet cell density and epithelial cell morphology.
This was a longitudinal clinical trial. Conjunctival impression cytology was performed on the superior palpebral conjunctiva in fifty-four eyes of twenty-seven neophyte contact lens wearers before and after three months of contact lens wear. Goblet cell density was determined by optical microscopy and epithelial cell morphology was classified according to the Tseng classification. Changes in goblet cell density as well as epithelial cell grading were determined. The effects of lens material and wearing modality on cytological changes were also investigated.
Goblet cell density reduced significantly by 85 ± 151 cells/mm(2) (p < 0.001) after three months of contact lens wear. Reduction in goblet cell density was associated with lens materials; it was higher in conventional hydrogel lenses in comparison to silicone-hydrogel lenses (p = 0.008). The highest reduction in goblet cell density was found with Nelfilcon A lens wear (p = 0.002) and the lowest with Comfilcon A lens wear (p = 0.414). There was no statistically significant difference in grading of epithelial metaplasia before and after three months of contact lens wear (p = 0.075). Age was not correlated with the reduction in goblet cell density (r = -0.196, p = 0.160) but it was associated with the change in epithelial cell morphology (p = 0.036).
Three months of soft contact lens wear statistically significantly reduced goblet cell density; however, no significant changes were found in the grading of epithelial metaplasia. Contact lenses with lower oxygen permeability, higher Young modulus and higher thickness highly affected the conjunctival cytology.
本研究旨在调查佩戴软性接触镜三个月对结膜杯状细胞密度和上皮细胞形态的影响。
这是一项纵向临床试验。对27名初戴接触镜者的54只眼在佩戴接触镜三个月前后,取上睑结膜进行结膜印迹细胞学检查。通过光学显微镜确定杯状细胞密度,并根据曾氏分类法对上皮细胞形态进行分类。确定杯状细胞密度的变化以及上皮细胞分级情况。还研究了镜片材料和佩戴方式对细胞学变化的影响。
佩戴接触镜三个月后,杯状细胞密度显著降低85±151个细胞/mm²(p<0.001)。杯状细胞密度的降低与镜片材料有关;与硅水凝胶镜片相比,传统水凝胶镜片中的杯状细胞密度降低幅度更高(p=0.008)。使用奈非康A镜片时杯状细胞密度降低幅度最大(p=0.002),而使用康菲康A镜片时降低幅度最小(p=0.414)。佩戴接触镜三个月前后,上皮化生分级无统计学显著差异(p=0.075)。年龄与杯状细胞密度的降低无关(r=-0.196,p=0.160),但与上皮细胞形态的变化有关(p=0.036)。
佩戴软性接触镜三个月在统计学上显著降低了杯状细胞密度;然而,上皮化生分级未发现显著变化。透氧性较低、杨氏模量较高和厚度较大的接触镜对结膜细胞学影响较大。