评价年轻亚裔软性隐形眼镜佩戴者和非佩戴者的泪膜和睑板腺形态变化。

Evaluation of tear film and the morphological changes of meibomian glands in young Asian soft contact lens wearers and non-wearers.

机构信息

Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China.

Eye Institute and School of Optometry, Tianjin, 300384, China.

出版信息

BMC Ophthalmol. 2020 Mar 4;20(1):84. doi: 10.1186/s12886-020-1328-2.

Abstract

BACKGROUND

The aim of this study was to explore the differences in terms of tear film and meibomian glands (MGs) between young Asian soft contact lens (CL) wearers and non-wearers.

METHODS

A prospective, cross-sectional observational study was conducted using 148 subjects (63 non-wearers, and 85 soft CL wearers who had been wearing CLs for more than 1 year) recruited from a clinic in Tianjin, China. All subjects first responded to an Ocular Surface Disease Index (OSDI) questionnaire and then underwent a standardized dry eye examination, which included measuring tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and corneal fluorescein staining (CFS). The MGs were evaluated via ImageJ, distorted MG count and the MG dropout were recorded.

RESULTS

Compared to the control group (non-wearers), the CL group recorded higher OSDI and CFS scores, lower TMH and NITBUT values, a larger distorted MG count, and larger MG dropout (all P < 0.05). Pearson correlation analysis found a correlation between MG dropout and the duration of CL use (r = 0.440, P < 0.001), OSDI (r = 0.298, P = 0.006), and CFS scores (r = 0.442, P < 0.001).

CONCLUSION

CL wearers showed higher MG dropout and reduced TMH and NITBUT, which likely contributes to severe CL-related dry eye symptoms. CL use may lead to a higher MG dropout rate, and the extent of the MG dropout presumably influences the tear film status in CL wearers.

摘要

背景

本研究旨在探讨年轻亚洲软性隐形眼镜(CL)佩戴者与非佩戴者之间在泪膜和睑板腺(MGs)方面的差异。

方法

采用前瞻性、横断面观察性研究方法,在中国天津的一家诊所招募了 148 名受试者(63 名非佩戴者和 85 名软性 CL 佩戴者,佩戴 CL 时间超过 1 年)。所有受试者首先回答眼表疾病指数(OSDI)问卷,然后进行标准化干眼检查,包括测量泪膜高度(TMH)、非侵入性泪膜破裂时间(NIBUT)和角膜荧光素染色(CFS)。使用 ImageJ 评估 MGs,记录变形 MG 计数和 MG 缺失。

结果

与对照组(非佩戴者)相比,CL 组的 OSDI 和 CFS 评分更高,TMH 和 NIBUT 值更低,变形 MG 计数更大,MG 缺失更大(均 P < 0.05)。Pearson 相关分析发现 MG 缺失与 CL 使用时间(r = 0.440,P < 0.001)、OSDI(r = 0.298,P = 0.006)和 CFS 评分(r = 0.442,P < 0.001)呈正相关。

结论

CL 佩戴者的 MG 缺失更多,TMH 和 NIBUT 更低,这可能导致严重的 CL 相关干眼症状。CL 使用可能导致更高的 MG 缺失率,MG 缺失的程度可能会影响 CL 佩戴者的泪膜状态。