Liu He-Ting, Jiang Zheng-Xuan, Tao Li-Ming
Department of Ophthalmology, the Second Hospital Affiliated to Anhui Medical University, Hefei 230601, Anhui Province, China.
Int J Ophthalmol. 2016 Mar 18;9(3):469-71. doi: 10.18240/ijo.2016.03.26. eCollection 2016.
The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective.
该研究旨在报告一种用于具有四个袢的可折叠人工晶状体的新型两点巩膜固定技术。人工晶状体通过2.8毫米角膜切口滑入前房,并在两个相对点的两个巩膜瓣下固定。所有患者术后的最佳矫正视力(BCVA)均显著优于术前BCVA。结果表明,可折叠人工晶状体的两点巩膜固定可能是可行且有效的。