Key Laboratory of Luminescence and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
Key Laboratory of Luminescence and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
Biosens Bioelectron. 2016 Nov 15;85:157-163. doi: 10.1016/j.bios.2016.05.007. Epub 2016 May 3.
The establishment of facile, rapid, sensitive and cost-effective protocols for the detection of heavy metals is of great significance for human health and environmental monitoring. Hereby, an ultra-facile and label-free immunoassay strategy was designed for detecting heavy metal ion by using Cu (II) as the model analyte. Cu (II) reacted previously with ethylenediaminetetraacetate (EDTA) was captured by immobilized monoclonal antibody for Cu (II)-EDTA chelate. Then Cu (II) was detected based on the self-enhancing effect of Cu (II)-EDTA chelate to luminol-H2O2 chemiluminescence reaction. The CL intensity is linear relative with Cu (II) concentration in a very wide range of 1.0-1000ng/mL, with a detection limit of 0.33ng/mL (S/N=3). Since the specificity of this proposed strategy relied on both the specificity of monoclonal antibody and the specificity of luminol-H2O2 system, it could avoid interference from most common ions. The proposed method was used successfully to detect Cu (II) in traditional Chinese medicine and environmental water samples with acceptable recovery values of 82-113%. This proof-of-principle work demonstrated the feasibility of the label-free immunoassay for heavy metal ions, and opened a new avenue for rapid screening and field assay for drug safety, environmental monitoring and clinical diagnosis.
建立简便、快速、灵敏、经济的重金属检测方法对于人类健康和环境监测具有重要意义。本研究设计了一种超简便、无标记的免疫分析策略,以 Cu(II)为模型分析物来检测重金属离子。Cu(II)与乙二胺四乙酸(EDTA)预先反应,被固定化的单克隆抗体捕获用于 Cu(II)-EDTA 螯合物。然后基于 Cu(II)-EDTA 螯合物对鲁米诺-H2O2 化学发光反应的自增强效应来检测 Cu(II)。CL 强度与 Cu(II)浓度在很宽的范围内(1.0-1000ng/mL)呈线性关系,检测限为 0.33ng/mL(S/N=3)。由于该策略的特异性依赖于单克隆抗体的特异性和鲁米诺-H2O2 体系的特异性,因此可以避免大多数常见离子的干扰。该方法成功地用于检测中药和环境水样中的 Cu(II),回收率在 82-113%之间,结果令人满意。这项初步研究证明了无标记免疫分析用于重金属离子检测的可行性,为药物安全性、环境监测和临床诊断的快速筛选和现场检测开辟了新途径。