Suppr超能文献

动脉导管未闭犬的斑点追踪超声心动图:经皮封堵对心脏力学的影响。

Speckle-Tracking Echocardiography in Dogs With Patent Ductus Arteriosus: Effect of Percutaneous Closure on Cardiac Mechanics.

作者信息

Spalla I, Locatelli C, Zanaboni A M, Brambilla P, Bussadori C

机构信息

Università degli Studi di Milano, Milano, Italy.

Clinica Veterinaria Gran Sasso, Milano, Italy.

出版信息

J Vet Intern Med. 2016 May;30(3):714-21. doi: 10.1111/jvim.13919.

Abstract

BACKGROUND

Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes.

HYPOTHESIS

A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA.

ANIMALS

Twenty-five client-owned dogs with PDA.

METHODS

Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR).

RESULTS

Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly.

CONCLUSION AND CLINICAL IMPORTANCE

Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and decreases to normal values in short axis (circumferential, radial, and transversal S/SR decreased to normal reference range).

摘要

背景

动脉导管未闭(PDA)是犬类最常见的先天性心脏缺陷之一,经皮闭合术能有效实现导管闭合;PDA闭合与血流动力学的突然变化有关。

假设

以往研究发现,PDA闭合后,通过M型或B型超声心动图评估的收缩功能标准参数会显著降低。斑点追踪超声心动图可以进一步深入了解PDA闭合对患有PDA的犬类心脏力学的影响。

动物

25只客户拥有的患有PDA的犬。

方法

前瞻性研究。在2年期间招募犬只。在PDA闭合前和闭合后24小时进行完整的超声心动图评估,包括标准参数(B型和M型中以体表面积指数化的舒张末期容积[EDVIB /M]、收缩末期容积[ESVIB /M]、舒张期[AlloD]和收缩期[AlloS]的体表面积标度、肺血流量与体循环血流量[Qs/Qp]、射血分数[EF]和缩短分数[FS]),以及先进的斑点追踪超声心动图(STE):整体纵向、径向、圆周和横向应变(S)以及应变率(SR)。

结果

动脉导管未闭闭合与EDVIM /B和ESVIM /B、AlloD和AlloS、SI、EF和FS在统计学上显著降低有关。观察到径向、横向和圆周S及SR的绝对值在统计学上显著降低,而纵向S和SR没有显著变化。

结论及临床意义

经皮方法闭合动脉导管未闭与由于负荷条件变化导致的传统超声心动图参数显著降低有关,但通过STE未发现收缩功能障碍的证据,因为S和SR值均未低于参考范围。短期内,长轴收缩力增强(闭合前后长S/SR值在统计学上无差异),短轴收缩力降至正常值(圆周、径向和横向S/SR降至正常参考范围)。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d644/4913567/aeb9caf3a367/JVIM-30-714-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验