The purpose of this investigation was to describe the time course of changes in physiological and perceptual variables during exhaustive endurance work with and without an air-supplied, full-facepiece, pressure-demand respirator. Thirty-eight healthy subjects (24 to 51 years of age) volunteered for this study. Treadmill speed was set at 5.5 kph (3.4 mph) and elevation was set at a level calculated to elicit 70% of a previously determined maximal aerobic capacity (VO2max). Subjects continued at this rate to exhaustion. Despite a constant work rate, VO2 and %VO2max increased during exercise and were significantly greater with the respirator (34.4 +/- 1.1 mL/kg.min; 84% VO2max) than without the respirator (31.9 +/- 1.1 mL/kg.min; 76% VO2max) at the "final" measurement point prior to termination of exercise by each subject. The final values for ventilation volume (VE) also were significantly greater with the respirator (89.2 +/- 3.4 L/min) than without (73.4 +/- 3.7 L/min). At the conclusion of the endurance walk, dyspnea index (VE/MMV.25) remained well below maximal values (with = 58.6 +/- 2%; without = 44.6 +/- 2%; p less than 0.001). Also, at the final period, no significant differences occurred in the subjects' perceptual ratings of work of breathing, yet work performance time was significantly reduced (p less than 0.0001) from 69.1 +/- 4.4 min (without) to 55.6 +/- 3.8 min (with). A significantly greater swing in peak pressure (maximum pressure measured within the facepiece of respirator), however, from inspired (PPi) to expired (PPe) occurred with the respirator (13.42 cmH2O) than without the respirator (9.25 cmH2O).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究的目的是描述在有和没有供气式全面罩、压力需求呼吸器的情况下,力竭性耐力运动期间生理和感知变量的变化时间进程。38名健康受试者(年龄在24至51岁之间)自愿参与本研究。跑步机速度设定为5.5公里/小时(3.4英里/小时),坡度设定为能引出先前测定的最大有氧能力(VO2max)的70%的水平。受试者以该速率持续运动至力竭。尽管工作速率恒定,但在运动过程中VO2和%VO2max仍有所增加,并且在每位受试者运动终止前的“最终”测量点,使用呼吸器时(34.4±1.1毫升/千克·分钟;84%VO2max)显著高于不使用呼吸器时(31.9±1.1毫升/千克·分钟;76%VO2max)。通气量(VE)的最终值在使用呼吸器时(89.2±3.4升/分钟)也显著高于不使用时(73.4±3.7升/分钟)。在耐力步行结束时,呼吸困难指数(VE/MMV.25)仍远低于最大值(使用时 = 58.6±2%;不使用时 = 44.6±2%;p<0.001)。此外,在最后阶段,受试者对呼吸功的感知评分没有显著差异,但工作表现时间显著缩短(p<0.0001),从不使用呼吸器时的69.1±4.4分钟降至使用呼吸器时的55.6±3.8分钟。然而,使用呼吸器时,面罩内测量的峰值压力(从吸气压力(PPi)到呼气压力(PPe))的波动幅度(13.42厘米水柱)显著大于不使用呼吸器时(9.25厘米水柱)。(摘要截选至250词)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验