Abstract

BACKGROUND

The goals of this study were to compare maximal metacarpophalangeal joint (MCPJ) flexion angles after application of a volar short arm splint at 3 different locations and verify the relations between the three different physical and radiological locations.

METHODS

Forty dominant hands of healthy subjects were analyzed in the study. We defined a transverse skin folding line as a line drawn from the radial aspect of the thenar crease to the ulnar aspect of the distal transverse palmar crease. The distal end of the volar short arm splint was applied on 3 parallel locations to this line. Location A was on this transverse skin folding line; location B was 1 cm proximal to location A; and location C was 1 cm distal to location A. Two orthopedic surgeons measured the maximal MCPJ flexion angles of each finger except the thumb with the application of a volar short arm splint at 3 different locations as well as without a splint as a control. Radiological locations of the 3 different distal ends of the volar short arm splint were also assessed by anteroposterior radiographs of the wrist.

RESULTS

When the splint was applied at location A and C, the maximal MCPJ flexion angle decreased to a mean of 83° (91% of control value) and 56° (62% of control value), respectively (compared to the control, p < 0.001). At location B, the maximal MCPJ flexion angle was a mean of 90° (99% of control value); no significant difference was observed compared to the control or without the splint (p = 0.103). On radiography, the average length from the metacarpal head to the distal end of the splint at all fingers decreased in the order of location B, A, and C (29 mm, 19 mm, and 10 mm, respectively; p < 0.001).

CONCLUSIONS

We recommend applying the distal end of a volar short arm splint at proximal 1 cm to the transverse skin folding line to preserve MCPJ motion perfectly, which is located at distal 44% of the whole metacarpal bone length radiologically.

摘要

背景

本研究的目的是比较在3个不同位置应用掌侧短臂夹板后掌指关节(MCPJ)的最大屈曲角度,并验证3个不同物理位置与放射学位置之间的关系。

方法

本研究分析了40名健康受试者的优势手。我们将一条横向皮肤褶皱线定义为从大鱼际纹桡侧到远侧掌横纹尺侧画出的一条线。掌侧短臂夹板的远端应用于与该线平行的3个位置。位置A位于这条横向皮肤褶皱线上;位置B在位置A近端1厘米处;位置C在位置A远端1厘米处。两名骨科医生测量了除拇指外每个手指在3个不同位置应用掌侧短臂夹板时以及不使用夹板作为对照时的最大MCPJ屈曲角度。还通过腕关节前后位X线片评估了掌侧短臂夹板3个不同远端的放射学位置。

结果

当夹板应用于位置A和C时,最大MCPJ屈曲角度分别降至平均83°(对照值的91%)和56°(对照值的62%)(与对照相比,p<0.001)。在位置B,最大MCPJ屈曲角度平均为90°(对照值的99%);与对照或不使用夹板相比,未观察到显著差异(p = 0.103)。在X线片上,所有手指从掌骨头到夹板远端的平均长度按位置B、A和C的顺序递减(分别为29毫米、19毫米和10毫米;p<0.001)。

结论

我们建议将掌侧短臂夹板的远端应用于横向皮肤褶皱线近端1厘米处,以完美保留MCPJ活动,从放射学角度看,该位置位于整个掌骨长度的远端44%处。