Suppr超能文献

使用CZT相机的超低剂量铊负荷-再分布方案(包括俯卧位成像)在肥胖患者中的可行性。

Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera.

作者信息

Kincl Vladimír, Kamínek Milan, Vašina Jiří, Panovský Roman, Havel Martin

机构信息

International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic.

Ist Department of Internal Medicine/Cardiology, St. Anne's University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic.

出版信息

Int J Cardiovasc Imaging. 2016 Sep;32(9):1463-1469. doi: 10.1007/s10554-016-0919-8. Epub 2016 Jun 2.

Abstract

High efficiency cadmium-zinc-telluride (CZT) cameras provide an opportunity to lower the injected activities of radiopharmaceuticals for single photon emission tomography (SPECT) myocardial perfusion imaging (MPI). The limits for reducing activities of thallium have not been determined, particularly in obese patients. After an injection of 0.7 megabecquerel (MBq) of thallium/kg, we collected an average 1.5 million counts for the 10-min acquisition in a pilot cohort of ten patients. After extrapolation, we reduced the administered activity to 0.5 MBq/kg to obtain the expected 1 million counts. We studied the image quality in 124 patients (86 men, 43 obese with body mass index over 30 kg/m) referred for MPI. The quality of images was assessed by a number of recorded counts and visually by a four-grade scale (one-poor quality, four-excellent quality). In non-obese and obese patients, the average number of recorded counts was 1.1 vs. 1.07 million counts for the 10-min stress acquisition, 1.04 vs. 1.06 million counts for the 13-min rest acquisition, and the average quality score was 3.97 vs. 3.90, respectively (p = NS).The mean administered activity was 39.2 ± 7 MBq for non-obese and 48.7 ± 6 for obese patients (p < 0.0001), and the calculated effective dose was 4.0 ± 0.7 and 4.9 ± 0.6 mSv respectively (p < 0.0001). The ultra-low-dose thallium stress-redistribution protocol, including post-stress prone imaging, provides good quality of images with a low radiation burden, even in obese patients.

摘要

高效碲镉锌(CZT)相机为降低用于单光子发射断层扫描(SPECT)心肌灌注成像(MPI)的放射性药物的注射活度提供了契机。减少铊活度的限度尚未确定,尤其是在肥胖患者中。在以0.7兆贝可勒尔(MBq)/千克的剂量注射铊后,我们在一个由10名患者组成的试验队列中进行了10分钟采集,平均采集到150万个计数。经过推算,我们将给药活度降低至0.5 MBq/千克,以获得预期的100万个计数。我们对124名因MPI前来就诊的患者(86名男性,43名肥胖患者,体重指数超过30千克/平方米)的图像质量进行了研究。图像质量通过记录的计数数量进行评估,并由一名医生采用四级评分标准进行视觉评估(一分——质量差,四分——质量优)。在非肥胖和肥胖患者中,10分钟负荷采集的记录计数平均数分别为110万和107万,13分钟静息采集的记录计数平均数分别为104万和106万,平均质量评分分别为3.97和3.90(p =无显著性差异)。非肥胖患者的平均给药活度为39.2±7 MBq,肥胖患者为48.7±6 MBq(p<0.0001),计算得到的有效剂量分别为4.0±0.7和4.9±0.6毫希沃特(mSv)(p<0.0001)。超低剂量铊负荷-再分布方案,包括负荷后俯卧位成像,即使在肥胖患者中也能提供低辐射负担的高质量图像。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验