Suppr超能文献

单呼吸法与肺容量复张技术在测量麻醉状态下婴幼儿总呼吸顺应性中的比较。

Comparison of the single breath and volume recruitment techniques in the measurement of total respiratory compliance in anesthetized infants and children.

作者信息

Shulman D L, Goodman A, Bar-Yishay E, Godfrey S

机构信息

Department of Anesthesia, Hadassah University Hospital, Jerusalem, Israel.

出版信息

Anesthesiology. 1989 Jun;70(6):921-7. doi: 10.1097/00000542-198906000-00007.

Abstract

Total respiratory compliance (Crs) has not previously been measured from the static pressure-volume (P-V) curve during spontaneous breathing in anesthesized infants and children. A single breath test and a volume recruitment maneuver for measuring Crs were applied to 18 infants and children breathing spontaneously during halothane anesthesia in order to determine the usefulness and reliability of these noninvasive tests for measuring static compliance during anesthesia. Crs from the single breath test (Crssb) was determined from the mask pressure plateau (P) during a brief end-inspiratory airway occlusion and the lung volume (V) from the passive expiration following release of the occlusion. Crs from the volume recruitment maneuver (Crsvr) was determined from P and V during a series of expiratory occlusions at progressively higher lung volumes. The P-V curves fit a polynomial curve with the convexity toward the pressure axis in most patients, and Crsvr was the tangent to the curve in the mid-tidal range. The tallest four patients did not show respiratory muscle relaxation during the occlusions with either test, and the single breath test could not be completed in an additional two patients. In the 12 patients (59-89 cm in height) in whom both tests were successful, Crssb correlated with, and was similar to, Crsvr. The intrasubject coefficient of variation was less with the single breath test (9.4 +/- 6.7%) than with the volume recruitment maneuver (15.0 +/- 7.1%). The authors conclude that both tests are simple, reliable, and rapid and give similar results for Crs in spontaneously breathing children (59-89 cm in height) anesthetized with halothane.

摘要

此前尚未在接受麻醉的婴幼儿自主呼吸过程中,通过静态压力-容积(P-V)曲线来测量总呼吸顺应性(Crs)。为了确定这些非侵入性测试在麻醉期间测量静态顺应性的有效性和可靠性,对18例在氟烷麻醉下自主呼吸的婴幼儿应用了单次呼吸测试和测量Crs的容量募集手法。单次呼吸测试所得Crs(Crssb)由短暂吸气末气道阻塞期间的面罩压力平台(P)以及阻塞解除后被动呼气时的肺容积(V)确定。容量募集手法所得Crs(Crsvr)由一系列在逐渐增加的肺容积时进行的呼气阻塞期间的P和V确定。在大多数患者中,P-V曲线拟合为一条凸向压力轴的多项式曲线,Crsvr是潮气量中期范围内曲线的切线。最高的4例患者在任何一项测试的阻塞期间均未表现出呼吸肌松弛,另有2例患者无法完成单次呼吸测试。在两项测试均成功的12例患者(身高59 - 89 cm)中,Crssb与Crsvr相关且相似。单次呼吸测试的受试者内变异系数(9.4 +/- 6.7%)低于容量募集手法(15.0 +/- 7.1%)。作者得出结论,对于接受氟烷麻醉的自主呼吸儿童(身高59 - 89 cm),这两项测试都简单、可靠且快速,并且在测量Crs方面给出相似的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验