潜水电脑的用户设置:在辅助保守潜水方面的可靠性。

User settings on dive computers: reliability in aiding conservative diving.

作者信息

Sayer Martin D J, Azzopardi Elaine, Sieber Arne

机构信息

UK National Facility for Scientific Diving hosted at the Scottish Association for Marine Science Laboratories, Scottish Association for Marine Science, Dunstaffnage Marine Laboratories, Dunbeg, Oban, Argyll PA37 1QA, Scotland,

West Scotland Centre for Diving and Hyperbaric Medicine, Scottish Association for Marine Science.

出版信息

Diving Hyperb Med. 2016 Jun;46(2):98-110.

Abstract

INTRODUCTION

Divers can make adjustments to diving computers when they may need or want to dive more conservatively (e.g., diving with a persistent (patent) foramen ovale). Information describing the effects of these alterations or how they compare to other methods, such as using enriched air nitrox (EANx) with air dive planning tools, is lacking.

METHODS

Seven models of dive computer from four manufacturers (Mares, Suunto, Oceanic and UWATEC) were subjected to single square-wave compression profiles (maximum depth: 20 or 40 metres' sea water, msw), single multi-level profiles (maximum depth: 30 msw; stops at 15 and 6 msw), and multi-dive series (two dives to 30 msw followed by one to 20 msw). Adjustable settings were employed for each dive profile; some modified profiles were compared against stand-alone use of EANx.

RESULTS

Dives were shorter or indicated longer decompression obligations when conservative settings were applied. However, some computers in default settings produced more conservative dives than others that had been modified. Some computer-generated penalties were greater than when using EANx alone, particularly at partial pressures of oxygen (PO₂) below 1.40 bar. Some computers 'locked out' during the multi-dive series; others would continue to support decompression with, in some cases, automatically-reduced levels of conservatism. Changing reduced gradient bubble model values on Suunto computers produced few differences.

DISCUSSION

The range of possible adjustments and the non-standard computer response to them complicates the ability to provide accurate guidance to divers wanting to dive more conservatively. The use of EANx alone may not always generate satisfactory levels of conservatism.

摘要

引言

潜水员在可能需要或希望更保守地潜水时(例如,患有持续性(开放)卵圆孔未闭进行潜水时),可以对潜水电脑进行调整。目前缺乏关于这些调整的效果的信息,也缺乏将其与其他方法(如在空气潜水计划工具中使用富氧空气氮氧混合气(EANx))进行比较的信息。

方法

对来自四个制造商(玛瑞斯、颂拓、欧西亚和优华特)的七种潜水电脑型号进行了单次方波压缩剖面(最大深度:20或40米海水,msw)、单次多级剖面(最大深度:30 msw;在15和6 msw处停留)以及多次潜水系列(两次潜水至30 msw,随后一次潜水至20 msw)测试。对每个潜水剖面采用了可调节设置;将一些修改后的剖面与单独使用EANx的情况进行了比较。

结果

当应用保守设置时,潜水时间缩短或显示出更长的减压义务。然而,一些处于默认设置的电脑产生的潜水比其他经过修改的电脑更保守。一些电脑产生的惩罚比单独使用EANx时更大,特别是在氧分压(PO₂)低于1.40巴时。在多次潜水系列中,一些电脑“锁定”;其他电脑在某些情况下会继续支持减压,且保守程度会自动降低。在颂拓电脑上更改降低梯度气泡模型值产生的差异很小。

讨论

可能的调整范围以及电脑对这些调整的非标准响应,使得为希望更保守潜水的潜水员提供准确指导的能力变得复杂。仅使用EANx可能并不总是能产生令人满意的保守程度。

相似文献

2
Risk mitigation in divers with persistent (patent) foramen ovale.
Diving Hyperb Med. 2019 Jun 30;49(2):77-78. doi: 10.28920/dhm49.2.77-78.
9
Patent foramen ovale and diving.
Cardiol Clin. 2005 Feb;23(1):97-104. doi: 10.1016/j.ccl.2004.10.005.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验