Yiğit Aydın, Yardım Yavuz, Çelebi Metin, Levent Abdulkadir, Şentürk Zühre
Yüzüncü Yıl University, Faculty of Pharmacy, Department of Analytical Chemistry, 65080 Van, Turkey.
Yüzüncü Yıl University, Faculty of Pharmacy, Department of Analytical Chemistry, 65080 Van, Turkey.
Talanta. 2016 Sep 1;158:21-29. doi: 10.1016/j.talanta.2016.05.046. Epub 2016 May 16.
A graphene-Nafion composite film was fabricated on the glassy carbon electrode (GR-NF/GCE), and used for simultaneous determination of paracetamol (PAR), aspirin (ASA) and caffeine (CAF). The electrochemical behaviors of PAR, ASA and CAF were investigated by cyclic voltammetry and square-wave adsorptive anodic stripping voltammetry. By using stripping one for simultaneous determination of PAR, ASA and CAF, their electrochemical oxidation peaks appeared at +0.64, 1.04 and 1.44V, and good linear current responses were obtained with the detection limits of 18ngmL(-1) (1.2×10(-9)M), 11.7ngmL(-1) (6.5×10(-8)M) and 7.3ngmL(-1) (3.8×10(-8)M), respectively. Finally, the proposed electrochemical sensor was successfully applied for quantifying PAR, ASA and CAF in commercial tablet formulations.
在玻碳电极上制备了石墨烯- 全氟磺酸复合膜(GR-NF/GCE),并用于同时测定对乙酰氨基酚(PAR)、阿司匹林(ASA)和咖啡因(CAF)。采用循环伏安法和方波吸附阳极溶出伏安法研究了PAR、ASA和CAF的电化学行为。通过溶出法同时测定PAR、ASA和CAF,它们的电化学氧化峰出现在+0.64、1.04和1.44V处,获得了良好的线性电流响应,检测限分别为18ngmL(-1)(1.2×10(-9)M)、11.7ngmL(-1)(6.5×10(-8)M)和7.3ngmL(-1)(3.8×10(-8)M)。最后,所提出的电化学传感器成功应用于商业片剂配方中PAR、ASA和CAF的定量分析。