OBJECTIVE To evaluate repeatability and reproducibility of right ventricular Tei index (RTX) values derived from dual pulsed-wave Doppler, conventional pulsed-wave Doppler, and tissue Doppler echocardiography and to investigate relationships and repeatability among the 3 methods in healthy dogs. ANIMALS 6 healthy adult Beagles. PROCEDURE Echocardiography was performed on each dog on different days for 2 weeks (3 times/d) by 2 echocardiographers. Intraobserver within- and between-day and interobserver coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) for RTXs derived from dual pulse-waved Doppler (RTXDPD), conventional pulsed-wave Doppler (RTXPD), and tissue Doppler (RTXTD) methods were determined. Degrees of agreement among RTX values derived from the 3 methods were assessed by modified Bland-Altman analysis. RESULTS Least squares mean (95% confidence interval) RTXtd was 0.50 (0.46 to 0.54), which was significantly higher than that for RTXDPD (0.27 [0.23 to 0.31]) and RTXPD (0.25 [0.21 to 0.29]). Agreement between RTXDPD and RTXPD was good (bias [mean difference], 0.04 [95% confidence interval, -0.03 to 0.10]). The RTXdpd had high within-day (CV, 6.1; ICC, 0.77) and interobserver (CV, 3.5; ICC, 0.83) repeatability, but between-day repeatability was not high. The RTXtd had high within-day repeatability (CV, 6.0; ICC, 0.80), but between-day and interobserver repeatability were not high. Within-day, between-day, and interobserver repeatability of RTXPD were not high. CONCLUSIONS AND CLINICAL RELEVANCE RTXdpd measurement was a repeatable and reproducible method of cardiac evaluation in healthy dogs. The RTXTD values were significantly higher than the RTXDPD and RTXPD values; therefore, RTX values derived from different echocardiographic methods should be interpreted with caution.
目的 评估双脉冲波多普勒、传统脉冲波多普勒和组织多普勒超声心动图得出的右心室Tei指数(RTX)值的可重复性和再现性,并研究这三种方法在健康犬中的相关性及可重复性。动物 6只健康成年比格犬。方法 由两名超声心动图检查人员在不同日期对每只犬进行为期2周的超声心动图检查(每天3次)。测定双脉冲波多普勒法(RTXDPD)、传统脉冲波多普勒法(RTXPD)和组织多普勒法(RTXTD)得出的RTX的观察者内日内和日间以及观察者间变异系数(CV)和组内相关系数(ICC)。采用改良的Bland-Altman分析评估三种方法得出的RTX值之间的一致性程度。结果 最小二乘均值(95%置信区间)RTXtd为0.50(0.46至0.54),显著高于RTXDPD(0.27 [0.23至0.31])和RTXPD(0.25 [0.21至0.29])。RTXDPD与RTXPD之间的一致性良好(偏差[平均差值],0.04 [95%置信区间,-0.03至0.10])。RTXdpd具有较高的日内(CV,6.1;ICC,0.77)和观察者间(CV,3.5;ICC,0.83)可重复性,但日间可重复性不高。RTXtd具有较高的日内可重复性(CV,6.0;ICC,0.80),但日间和观察者间可重复性不高。RTXPD的日内、日间和观察者间可重复性均不高。结论及临床意义 RTXdpd测量是健康犬心脏评估的一种可重复且可再现的方法。RTXTD值显著高于RTXDPD和RTXPD值;因此,对不同超声心动图方法得出的RTX值进行解读时应谨慎。