Suppr超能文献

经胸超声心动图测量心脏功能:正常纯血马的每日变异性和可重复性

Measurement of cardiac function by transthoracic echocardiography: day to day variability and repeatability in normal Thoroughbred horses.

作者信息

Young L E, Scott G R

机构信息

The Centre for Equine Studies, The Animal Health Trust, Newmarket, Suffolk, UK.

出版信息

Equine Vet J. 1998 Mar;30(2):117-22. doi: 10.1111/j.2042-3306.1998.tb04470.x.

Abstract

In order to assess the reliability and repeatability of transthoracic echocardiography for detecting serial changes in cardiac function in horses, day to day variability of a number of echocardiographic indices of ventricular function were studied. The variables investigated were, from 2-dimensional (2-D) and M-mode echocardiography - aortic diameter in systole (Aos), pulmonary artery diameter in systole (Pas), left ventricular internal diameter in systole (LLVIDs) and diastole (LLVIDd), and left ventricular fractional shortening (%FS) and estimated ejection fraction (EF). From pulsed Doppler echocardiography - maximum velocity (Vmax) and acceleration (dv/dtmax) of aortic and pulmonary arterial blood flow, left and right ventricular velocity time integral (AoVTI and PAVTI) and estimated cardiac output (COLV, and CORV), left and right ventricular ejection time (LVET and RVET) and pre-ejection period (LVPEP and RVPEP), and heart rate. Maximum velocity of early rapid right ventricular filling (ETV) and late right ventricular filling due to right atrial contraction (ATV) were measured. Maximum deceleration and time for deceleration of early rapid filling (dv/dtTV and dt TV) were also determined. Seven healthy mature Thoroughbred horses weighing 490-600 kg were studied. The horses' management regimes and environment were standardised and an echocardiographic examination was carried out on each horse at the same time every day for 6 consecutive days. Two statistical measures of repeatability were calculated for each variable: the intraclass correlation coefficient (rI) and the 95% confidence intervals for error free value of a single measurement. In general, the dimensions and indices of cardiac function derived from 2-D and M-mode echocardiography showed better repeatability for individual horses than did the indices derived from Doppler echocardiography. Overall the 95% confidence intervals for an error-free value of all variables derived from Doppler echocardiography were wide. This must be appreciated when attributing serial measured changes of Doppler echocardiographic variables in an individual animal to effects of a treatment or disease.

摘要

为了评估经胸超声心动图检测马匹心功能系列变化的可靠性和可重复性,研究了多个心室功能超声心动图指标的每日变异性。研究的变量包括二维(2-D)和M型超声心动图的指标——收缩期主动脉直径(Aos)、收缩期肺动脉直径(Pas)、收缩期左心室内径(LLVIDs)和舒张期左心室内径(LLVIDd),以及左心室缩短分数(%FS)和估计射血分数(EF)。脉冲多普勒超声心动图的指标包括——主动脉和肺动脉血流的最大速度(Vmax)和加速度(dv/dtmax)、左心室和右心室速度时间积分(AoVTI和PAVTI)以及估计心输出量(COLV和CORV)、左心室和右心室射血时间(LVET和RVET)以及射血前期(LVPEP和RVPEP),还有心率。测量了右心室早期快速充盈(ETV)和右心房收缩导致的右心室晚期充盈(ATV)的最大速度。还确定了早期快速充盈的最大减速和减速时间(dv/dtTV和dt TV)。对7匹体重490 - 600 kg的健康成年纯种马进行了研究。对马匹的管理方式和环境进行了标准化,并且连续6天每天在同一时间对每匹马进行超声心动图检查。为每个变量计算了两种重复性统计量:组内相关系数(rI)和单次测量无误差值的95%置信区间。总体而言,二维和M型超声心动图得出的心脏功能维度和指标对个体马匹来说比多普勒超声心动图得出的指标具有更好的可重复性。总体而言,多普勒超声心动图得出的所有变量无误差值的95%置信区间都很宽。在将个体动物多普勒超声心动图变量的系列测量变化归因于治疗或疾病的影响时,必须认识到这一点。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验