• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

关节镜检查时冲洗液流出的高位位置:一项实验研究

Elevated position of the irrigation outflow during arthroscopy: an experimental study.

作者信息

Dolk T, Augustini B G

机构信息

Department of Orthopedic Surgery, Regional Hospital, Orebro, Sweden.

出版信息

Arthroscopy. 1989;5(2):93-6. doi: 10.1016/0749-8063(89)90002-9.

DOI:10.1016/0749-8063(89)90002-9
PMID:2736013
Abstract

The purpose of this study was to investigate different types of irrigation systems and to record pressures and flows in a joint model. Gravity inflow and three different pumps were compared, and the level of the outflow in relation to the model was tested. Flow rates of 100-200 ml/min and pressures ranging from negative to 100 mm Hg were found. There were minor differences between the irrigation systems, mainly concerning safety aspects. Elevated position of the outflow could be of value in controlling and optimizing pressures and flows during arthroscopy.

摘要

本研究的目的是调查不同类型的冲洗系统,并记录关节模型中的压力和流量。比较了重力流入和三种不同的泵,并测试了相对于模型的流出水平。发现流速为100 - 200毫升/分钟,压力范围为负至100毫米汞柱。冲洗系统之间存在微小差异,主要涉及安全方面。流出物的高位在关节镜检查期间控制和优化压力及流量方面可能具有价值。

相似文献

1
Elevated position of the irrigation outflow during arthroscopy: an experimental study.关节镜检查时冲洗液流出的高位位置:一项实验研究
Arthroscopy. 1989;5(2):93-6. doi: 10.1016/0749-8063(89)90002-9.
2
Elevated position of suction outflow during arthroscopic motorized surgery: an experimental study.
Arthroscopy. 1989;5(2):97-100. doi: 10.1016/0749-8063(89)90003-0.
3
Three irrigation systems for motorized arthroscopic surgery: a comparative experimental and clinical study.
Arthroscopy. 1989;5(4):307-14. doi: 10.1016/0749-8063(89)90147-3.
4
Arthroscopy and irrigation control.关节镜检查与冲洗控制
Arthroscopy. 1986;2(1):46-50. doi: 10.1016/s0749-8063(86)80010-x.
5
Gravity Fluid Flow More Accurately Reflects Joint Fluid Pressure Compared With Commercial Peristaltic Pump Systems in a Cadaveric Model.重力流在尸体模型中比商业蠕动泵系统更能准确反映关节液压力。
Arthroscopy. 2018 Dec;34(12):3132-3138. doi: 10.1016/j.arthro.2018.05.033. Epub 2018 Sep 5.
6
The use of an infusion pump in arthroscopy.
Arthroscopy. 1986;2(1):41-5. doi: 10.1016/s0749-8063(86)80009-3.
7
[Analysis on the arthroscopy efficacy with different irrigation times for the treatment of suppurative knee arthritis in elder patients].[不同冲洗时间关节镜治疗老年化脓性膝关节炎的疗效分析]
Zhongguo Gu Shang. 2017 Apr 25;30(4):300-303. doi: 10.3969/j.issn.1003-0034.2017.04.003.
8
Arthrex AR-6400 and AR-6475 arthroscopy pumps can deliver excessive pressure without alerting user.
Health Devices. 2010 Apr;39(4):134-6.
9
Optimizing lavage during knee arthroscopy: a three-dimensional MRI study.膝关节镜检查中灌洗的优化:一项三维 MRI 研究。
J Magn Reson Imaging. 2013 Jan;37(1):201-7. doi: 10.1002/jmri.23787. Epub 2012 Aug 31.
10
Complications associated with the use of an infusion pump during knee arthroscopy.膝关节镜检查期间使用输液泵相关的并发症。
Arthroscopy. 1992;8(2):224-8. doi: 10.1016/0749-8063(92)90040-i.

引用本文的文献

1
Behavior of arthroscopic irrigation systems.关节镜冲洗系统的性能
Knee Surg Sports Traumatol Arthrosc. 2005 Apr;13(3):238-46. doi: 10.1007/s00167-004-0573-x. Epub 2005 Jan 4.