Suppr超能文献

用于检测糖化血红蛋白(HbA1c)的一次性使用电化学免标记免疫传感器,采用差分脉冲伏安法(DPV)。

Single-Use Disposable Electrochemical Label-Free Immunosensor for Detection of Glycated Hemoglobin (HbA1c) Using Differential Pulse Voltammetry (DPV).

作者信息

Molazemhosseini Alireza, Magagnin Luca, Vena Pasquale, Liu Chung-Chiun

机构信息

Dipartimento Chimica Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Via Mancinelli 7, 20131 Milan, Italy.

Department of Chemical & Biomolecular Engineering and Electronics Design Center, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA.

出版信息

Sensors (Basel). 2016 Jul 1;16(7):1024. doi: 10.3390/s16071024.

Abstract

A single-use disposable in vitro electrochemical immunosensor for the detection of HbA1c in undiluted human serum using differential pulse voltammetry (DPV) was developed. A three-electrode configuration electrochemical biosensor consisted of 10-nm-thin gold film working and counter electrodes and a thick-film printed Ag/AgCl reference electrode was fabricated on a polyethylene terephthalate (PET) substrate. Micro-fabrication techniques including sputtering vapor deposition and thick-film printing were used to fabricate the biosensor. This was a roll-to-roll cost-effective manufacturing process making the single-use disposable in vitro HbA1c biosensor a reality. Self-assembled monolayers of 3-Mercaptopropionic acid (MPA) were employed to covalently immobilize anti-HbA1c on the surface of gold electrodes. Electrochemical impedance spectroscopy (EIS) and X-ray photoelectron spectroscopy (XPS) confirmed the excellent coverage of MPA-SAM and the upward orientation of carboxylic groups. The hindering effect of HbA1c on the ferricyanide/ferrocyanide electron transfer reaction was exploited as the HbA1c detection mechanism. The biosensor showed a linear range of 7.5-20 µg/mL of HbA1c in 0.1 M PBS. Using undiluted human serum as the test medium, the biosensor presented an excellent linear behavior (R² = 0.999) in the range of 0.1-0.25 mg/mL of HbA1c. The potential application of this biosensor for in vitro measurement of HbA1c for diabetic management was demonstrated.

摘要

开发了一种一次性体外电化学免疫传感器,用于使用差分脉冲伏安法(DPV)检测未稀释人血清中的糖化血红蛋白(HbA1c)。一种三电极配置的电化学生物传感器由厚度为10纳米的金薄膜工作电极和对电极以及厚膜印刷的Ag/AgCl参比电极组成,该传感器在聚对苯二甲酸乙二醇酯(PET)基板上制造。采用包括溅射气相沉积和厚膜印刷在内的微加工技术来制造生物传感器。这是一种卷对卷的具有成本效益的制造工艺,使一次性体外HbA1c生物传感器成为现实。使用3-巯基丙酸(MPA)的自组装单分子层将抗HbA1c共价固定在金电极表面。电化学阻抗谱(EIS)和X射线光电子能谱(XPS)证实了MPA自组装单分子层的良好覆盖以及羧基的向上取向。利用HbA1c对铁氰化物/亚铁氰化物电子转移反应的阻碍作用作为HbA1c的检测机制。该生物传感器在0.1 M磷酸盐缓冲液(PBS)中对HbA1c的线性检测范围为7.5-20 µg/mL。以未稀释的人血清作为测试介质,该生物传感器在0.1-0.25 mg/mL的HbA1c范围内呈现出优异的线性行为(R² = 0.999)。证明了这种生物传感器在体外测量HbA1c用于糖尿病管理方面的潜在应用。