Parija S C, Kasinathan S, Rao R S
Department of Microbiology, Fawaharlal Institute of Postgraduate Medical Education & Research, Pondicherry, India.
J Trop Med Hyg. 1989 Jun;92(3):221-6.
A successful modification of the indirect haemagglutination (IHA) test as a simple and rapid diagnostic procedure for serodiagnosis of amoebiasis at a primary health centre (PHC) level laboratory has been described in the present study. In this modified IHA test, the chick red blood cells (RBC), stabilized by the double aldehyde method, could be sensitized with amoebic antigen and then stored at 4 degrees C for up to 45 days for their subsequent use, as ready-made reagent directly in the IHA, without loss of sensitivity. The chick red cells settled quickly and their haemagglutination pattern could be determined within 30 to 45 min of incubation at room temperature with test sera. The IHA using double-aldehyde stabilized (DAS) chick cells, showed equal sensitivity and specificity with that of IHA using human O cells in diagnosing cases with different manifestations of amoebiasis. With the use of stored sensitized DAS chick cells directly in the IHA, the test could be performed and results obtained within 60 to 90 min of receipt of the sera to be tested. This makes IHA a simple and rapid procedure for its adaptation at a PHC level laboratory for the serodiagnosis of amoebiasis.
本研究描述了对间接血凝试验(IHA)的一种成功改良,该改良使其成为基层医疗中心(PHC)实验室用于阿米巴病血清学诊断的一种简单快速的诊断方法。在这种改良的IHA试验中,通过双醛法稳定的鸡红细胞(RBC)可用阿米巴抗原致敏,然后在4℃下保存长达45天以供后续使用,可作为现成的试剂直接用于IHA,且不会丧失敏感性。鸡红细胞沉降迅速,在室温下与检测血清孵育30至45分钟内即可确定其血凝模式。使用双醛稳定(DAS)鸡细胞的IHA在诊断不同表现的阿米巴病病例时,与使用人O细胞的IHA具有相同的敏感性和特异性。直接在IHA中使用储存的致敏DAS鸡细胞,在收到待检测血清后60至90分钟内即可进行试验并获得结果。这使得IHA成为一种简单快速的方法,适用于基层医疗中心实验室进行阿米巴病的血清学诊断。