Abstract

OBJECTIVES

To compare iodine content (IC) of solitary lung cancer using dynamic measurements of CT attenuation (Hounsfield Units, HU) and to correlate their quantitative CT data with expressions of vascular endothelial growth factor (VEGF), epidermal growth factor receptor (EGFR) and hypoxia-inducible factor-1α (HIF-1α) using immunostaining methods.

METHODS

This study included 18 patients with adenocarcinoma, who undergone dual energy dynamic multiphase CT to examine solitary lung nodules (6 part-solid and 12 solid nodules). Tumor size was 21.1 mm±8.1 (9-39mm) [Mean±SD (range)]. Contrast volume was determined by weight (2ml/kg). Contrast volume and injection rate were 110.5 ml±17.2 (80-144ml) and 1.84ml/s±0.30 (1.3-2.4ml/s), respectively. Enhancement values ([CT value at each delayed scan-CT value at unenhanced scan]) and net enhancement values ([peak CT value-CT value at unenhanced scan]) were calculated in HU from 65keV monochromatic image. IC at each delayed scan was measured in mg/cm(3) from the iodine-water material decomposition pair on the advantage workstation VolumeShare4. Immunostaining using VEGF, EGFR, and HIF-1α was performed by two pathologists, who evaluated the expression level of them subjectively. Statistical analyses were performed with rank correlation tests and regression analysis.

RESULTS

IC at 2- and 3-minute delayed scan (x) and immunostaining score of HIF-1α (y) showed a significantly positive correlation (r=0.64 and 0.52, p=0.004 and 0.03): regression equation, y=1.34+0.58x and y=1.51+0.55x, respectively.

CONCLUSIONS

Dual-energy dynamic multiphase CT can measure iodine content in lung adenocarcinoma. Iodine content at 2- and 3-minute delayed scan might correlate with the expression level of HIF-1α.

摘要

目的

通过动态测量CT衰减值(亨氏单位,HU)比较孤立性肺癌的碘含量(IC),并采用免疫染色方法将其定量CT数据与血管内皮生长因子(VEGF)、表皮生长因子受体(EGFR)和缺氧诱导因子-1α(HIF-1α)的表达相关联。

方法

本研究纳入18例腺癌患者,这些患者接受了双能量动态多期CT检查以评估孤立性肺结节(6个部分实性结节和12个实性结节)。肿瘤大小为21.1 mm±8.1(9 - 39mm)[平均值±标准差(范围)]。对比剂用量通过体重确定(2ml/kg)。对比剂用量和注射速率分别为110.5 ml±17.2(80 - 144ml)和1.84ml/s±0.30(1.3 - 2.4ml/s)。在65keV单色图像上以HU计算增强值([每次延迟扫描时的CT值 - 平扫时的CT值])和净增强值([峰值CT值 - 平扫时的CT值])。在优势工作站VolumeShare4上根据碘 - 水物质分解对在每次延迟扫描时以mg/cm³测量IC。由两名病理学家使用VEGF、EGFR和HIF-1α进行免疫染色,他们主观评估其表达水平。采用秩相关检验和回归分析进行统计分析。

结果

2分钟和3分钟延迟扫描时的IC(x)与HIF-1α的免疫染色评分(y)显示出显著正相关(r = 0.64和0.52,p = 0.004和0.03):回归方程分别为y = 1.34 + 0.58x和y = 1.51 + 0.55x。

结论

双能量动态多期CT可测量肺腺癌中的碘含量。2分钟和3分钟延迟扫描时的碘含量可能与HIF-1α的表达水平相关。