Clarke Clare L, Taylor Judith, Crighton Linda J, Goodbrand James A, McMurdo Marion E T, Witham Miles D
Ninewells Hospital and Medical School, School of Medicine, University of Dundee, Dundee, UK.
Aging Clin Exp Res. 2017 Jun;29(3):451-457. doi: 10.1007/s40520-016-0604-8. Epub 2016 Jul 19.
Studying physical activity (PA) trends in older populations and potential interventions for increasing PA is important, as PA is a factor in many age-related health outcomes such as chronic disease, premature mortality, physical function and injuries from falls. Objective measures of PA provide valuable information regarding the functional impact that ageing and chronic disease states may have on a patient's life.
The purpose of this study was to test the validity of the AX3 PA monitor in an older population and to investigate whether the AX3 is a valid measure of distinct types or levels of activity in older people with a spectrum of mobility.
Validity of the AX3 PA monitor was tested using the RT3 as a means of cross-validating the AX3. Study participants wore both the AX3 and the RT3 accelerometers, positioned on their non-dominant side, whilst completing a series of standardised everyday activities.
Although overall correlation was high (r > 0.8) between the RT3 and lower-limb-mounted AX3 counts, the correlation between the two devices was much stronger for walking activity than for any of the non-walking activities.
Activity counts at all lower limb positions for the AX3 and RT3 were highly correlated. Correlation between wrist-mounted AX3 counts and lower limb AX3 counts was only moderate, and worsened when walking aids were in use.
The results of this study indicate that the AX3 monitor is a valid tool, which might be used to objectively measure walking activity in older functionally impaired adults, a welcome finding for this under-researched area.
研究老年人群的身体活动(PA)趋势以及增加PA的潜在干预措施非常重要,因为PA是许多与年龄相关的健康结果的一个因素,如慢性病、过早死亡、身体功能以及跌倒受伤等。PA的客观测量提供了有关衰老和慢性病状态可能对患者生活产生的功能影响的有价值信息。
本研究的目的是测试AX3 PA监测仪在老年人群中的有效性,并调查AX3是否是一种有效的测量工具,用于测量具有不同活动能力的老年人的不同类型或水平的活动。
使用RT3作为交叉验证AX3的手段来测试AX3 PA监测仪的有效性。研究参与者在完成一系列标准化日常活动时,在非优势侧佩戴AX3和RT3加速度计。
尽管RT3与安装在下肢的AX3计数之间的总体相关性很高(r>0.8),但两种设备之间对于步行活动的相关性比对任何非步行活动的相关性要强得多。
AX3和RT3在所有下肢位置的活动计数高度相关。安装在手腕上的AX3计数与下肢AX3计数之间的相关性仅为中等,并且在使用助行器时相关性会变差。