自适应统计迭代重建技术在碘负荷降低患者的64层双能量计算机断层扫描肺血管造影中的有效性:与标准计算机断层扫描肺血管造影的比较

Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography.

作者信息

Lee Ji Won, Lee Geewon, Lee Nam Kyung, Moon Jin Il, Ju Yun Hye, Suh Young Ju, Jeong Yeon Joo

机构信息

From the *Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan; †Department of Biomedical Engineering, Yonsei University, Wonju; and ‡Department of Biomedical Sciences, School of Medicine, Inha University, Incheon, Republic of Korea.

出版信息

J Comput Assist Tomogr. 2016 Sep-Oct;40(5):777-83. doi: 10.1097/RCT.0000000000000443.

Abstract

OBJECTIVE

The aim of the study was to assess the effectiveness of the adaptive statistical iterative reconstruction (ASIR) for dual-energy computed tomography pulmonary angiography (DE-CTPA) with a reduced iodine load.

MATERIALS AND METHODS

One hundred forty patients referred for chest CT were randomly divided into a DE-CTPA group with a reduced iodine load or a standard CTPA group. Quantitative and qualitative image qualities of virtual monochromatic spectral (VMS) images with filtered back projection (VMS-FBP) and those with 50% ASIR (VMS-ASIR) in the DE-CTPA group were compared. Image qualities of VMS-ASIR images in the DE-CTPA group and ASIR images in the standard CTPA group were also compared.

RESULTS

All quantitative and qualitative indices, except attenuation value of pulmonary artery in the VMS-ASIR subgroup, were superior to those in the VMS-FBP subgroup (all P < 0.001). Noise and signal-to-noise ratio of VMS-ASIR images were superior to those of ASIR images in the standard CTPA group (P < 0.001 and P = 0.007, respectively). Regarding qualitative indices, noise was significantly lower in VMS-ASIR images of the DE-CTPA group than in ASIR images of the standard CTPA group (P = 0.001).

CONCLUSIONS

The ASIR technique tends to improve the image quality of VMS imaging. Dual-energy computed tomography pulmonary angiography with ASIR can reduce contrast medium volume and produce images of comparable quality with those of standard CTPA.

摘要

目的

本研究旨在评估自适应统计迭代重建(ASIR)技术在减少碘负荷的双能量计算机断层扫描肺血管造影(DE-CTPA)中的有效性。

材料与方法

将140例因胸部CT检查而就诊的患者随机分为低碘负荷DE-CTPA组或标准CTPA组。比较DE-CTPA组中采用滤波反投影(VMS-FBP)的虚拟单色光谱(VMS)图像以及采用50%ASIR的VMS图像(VMS-ASIR)的定量和定性图像质量。还比较了DE-CTPA组中VMS-ASIR图像与标准CTPA组中ASIR图像的质量。

结果

除VMS-ASIR亚组中肺动脉的衰减值外,所有定量和定性指标均优于VMS-FBP亚组(所有P<0.001)。VMS-ASIR图像的噪声和信噪比优于标准CTPA组中的ASIR图像(分别为P<0.001和P=0.007)。在定性指标方面,DE-CTPA组VMS-ASIR图像的噪声明显低于标准CTPA组的ASIR图像(P=0.001)。

结论

ASIR技术倾向于改善VMS成像的图像质量。采用ASIR的双能量计算机断层扫描肺血管造影可以减少对比剂用量,并产生与标准CTPA质量相当的图像。