Suppr超能文献

对使用戈尔特斯(Gore-Tex)前交叉韧带替代物的患者进行的松弛度仪器测量。

Instrumented measurements of laxity in patients who have a Gore-Tex anterior cruciate-ligament substitute.

作者信息

Markolf K L, Pattee G A, Strum G M, Gallick G S, Sherman O H, Nuys V, Dorey F J

机构信息

Division of Orthopaedic Surgery, University of California, Los Angeles 90024.

出版信息

J Bone Joint Surg Am. 1989 Jul;71(6):887-93.

PMID:2745484
Abstract

Twenty patients who had substitution of the anterior cruciate ligament with a Gore-Tex synthetic ligament were evaluated preoperatively and postoperatively with the University of California at Los Angeles instrumented clinical-testing apparatus, which records anterior-posterior force versus displacement-response curves of the tibia with respect to the femur at 20 degrees of flexion of the knee. The mean age of the patients was thirty-three years (range, nineteen to fifty-four years). The duration of follow-up ranged from twenty-four to forty-four months (mean, thirty-one months). The mean preoperative difference in anterior laxity between the injured knee and the normal knee (4.5 millimeters with neutral rotation of the foot) was unchanged two years after the operation; at that time, all patients had an anterior laxity of the injured knee of more than eight millimeters, and 90 per cent had a difference in anterior laxity of more than two millimeters between sides. The mean values for anterior stiffness at fifty and 100 newtons of anterior force were unchanged after the operation, remaining at 40 to 50 per cent of normal levels. At 200 newtons, or 20.4 kilograms (forty-five pounds) of anterior force, the mean stiffness of the involved knee was 11 to 17 per cent greater than that of the normal knee. Clinically, there were improvements in both subjective and objective knee-rating scores. All but four patients had a reduction of at least one grade in the pivot-shift score; in thirteen, the pivot-shift sign was eliminated.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

对20例采用Gore-Tex人工韧带置换前交叉韧带的患者,术前及术后均使用加利福尼亚大学的仪器化临床测试设备进行评估,该设备可记录膝关节在20度屈曲时胫骨相对于股骨的前后力与位移响应曲线。患者的平均年龄为33岁(范围为19至54岁)。随访时间为24至44个月(平均31个月)。术后两年,患侧膝关节与正常膝关节术前的平均前向松弛度差异(足部中立旋转时为4.5毫米)未改变;此时,所有患者患侧膝关节的前向松弛度均超过8毫米,90%的患者两侧前向松弛度差异超过2毫米。术后,50牛顿和100牛顿前向力时的前向刚度平均值未改变,仍为正常水平的40%至50%。在200牛顿(即20.4千克,45磅)的前向力作用下,患侧膝关节的平均刚度比正常膝关节大11%至17%。临床上,主观和客观的膝关节评分均有改善。除4例患者外,所有患者的轴移评分至少降低了一个等级;13例患者的轴移征消失。(摘要截短至250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验