Daniel D M, Malcom L L, Losse G, Stone M L, Sachs R, Burks R
J Bone Joint Surg Am. 1985 Jun;67(5):720-6.
We performed instrumented measurement of anterior-posterior laxity of the knee in thirty-three cadaver specimens, 338 normal subjects, and eighty-nine patients with unilateral disruption of the anterior cruciate ligament. The test instrument was the Medmetric knee arthrometer, model KT-2000. We measured total anterior-posterior laxity, produced by anterior and posterior loads of eighty-nine newtons (twenty pounds), and the anterior compliance index. The total anterior-posterior laxity is composed of an anterior displacement and a posterior displacement; these are measured from a testing reference position, defined as the resting position of the knee after applying and then releasing a posterior load of eighty-nine newtons. The anterior compliance index is defined as the anterior displacement between an anterior load of sixty-seven newtons and one of eighty-nine newtons. All tests were performed with the knee held on a thigh support that placed the knee in 20 +/- 5 degrees of flexion. The mean anterior displacement at eighty-nine newtons was 5.7 millimeters in a group of normal subjects and 13.0 millimeters in a group of patients with a disrupted anterior cruciate ligament. Ninety-two per cent of the normal subjects had a left knee-right knee difference in anterior displacement of no more than two millimeters, while 96 per cent of the patients with a unilateral disruption of the anterior cruciate ligament had an injured knee-normal knee difference in anterior displacement of more than two millimeters. Ninety-three per cent of the normal subjects had a difference in the left-right compliance index of no more than 0.5 millimeter, and 85 per cent of the patients with unilateral disruption of the anterior cruciate ligament had a difference in the compliance index of the injured and normal sides of more than 0.5 millimeter.
我们对33个尸体标本、338名正常受试者以及89名单侧前交叉韧带断裂的患者进行了膝关节前后松弛度的仪器测量。测试仪器为Medmetric KT - 2000型膝关节测角仪。我们测量了由89牛顿(20磅)的前后负荷产生的总前后松弛度以及前顺应性指数。总前后松弛度由前移位和后移位组成;这些移位是从一个测试参考位置测量的,该参考位置定义为在施加并随后释放89牛顿的后负荷后膝关节的静止位置。前顺应性指数定义为67牛顿的前负荷与89牛顿的前负荷之间的前移位。所有测试均在将膝关节置于大腿支撑物上进行,该支撑物使膝关节处于20±5度的屈曲状态。在一组正常受试者中,89牛顿负荷下的平均前移位为5.7毫米,而在一组前交叉韧带断裂的患者中为13.0毫米。92%的正常受试者左右膝关节前移位差异不超过2毫米,而96%的单侧前交叉韧带断裂患者患侧膝关节与正常膝关节的前移位差异超过2毫米。93%的正常受试者左右顺应性指数差异不超过0.5毫米,85%的单侧前交叉韧带断裂患者患侧与正常侧的顺应性指数差异超过0.5毫米。