Glycogen storage disease type III is an inherited metabolic disorder characterized by liver and muscle impairment. This study aimed to identify promising muscle function measures for future studies on natural disease progression and therapeutic trials. The age-effect on the manual muscle testing (MMT), the hand-held dynamometry (HHD), the motor function measure (MFM) and the Purdue pegboard test was evaluated by regression analysis in a cross-sectional retrospective single site study. In patients aged between 13 and 56 years old, the Purdue pegboard test and dynamometry of key pinch and knee extension strength were age-sensitive with annual losses of 1.49, 1.10 and 0.70% of the predicted values (%pred), respectively. The MFM score and handgrip strength were also age-sensitive but only in patients older than 29 and 37 years old with annual losses of 1.42 and 1.84%pred, respectively. Muscle strength assessed by MMT and elbow extension measured by HHD demonstrated an annual loss of less than 0.50%pred and are thus unlikely to be promising outcome measures for future clinical trials. In conclusion, our results identified age-sensitive outcomes from retrospective data and may serve for future longitudinal studies in which an estimation of the minimal number of subjects is provided.
III型糖原贮积病是一种以肝脏和肌肉损害为特征的遗传性代谢紊乱疾病。本研究旨在确定有前景的肌肉功能测量指标,用于未来关于自然疾病进展和治疗试验的研究。在一项横断面回顾性单中心研究中,通过回归分析评估了年龄对手动肌力测试(MMT)、手持测力计(HHD)、运动功能测量(MFM)和普渡钉板试验的影响。在年龄介于13至56岁的患者中,普渡钉板试验以及关键捏力和膝关节伸展力量的测力计测量对年龄敏感,预测值(%pred)的年损失率分别为1.49%、1.10%和0.70%。MFM评分和握力也对年龄敏感,但仅在年龄大于29岁和37岁的患者中出现,年损失率分别为1.42%pred和1.84%pred。通过MMT评估的肌肉力量以及通过HHD测量的肘关节伸展显示年损失率小于0.50%pred,因此不太可能成为未来临床试验中有前景的结果测量指标。总之,我们的结果从回顾性数据中确定了对年龄敏感的结果,可为未来的纵向研究提供参考,其中还提供了受试者最小数量的估计。