Suppr超能文献

针对马尸体骶髂关节区域的两种超声引导注射技术的比较。

Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

作者信息

Stack John David, Bergamino Chiara, Sanders Ruth, Fogarty Ursula, Puggioni Antonella, Kearney Clodagh, David Florent

机构信息

John David Stack, MVB, MSc, MRCVS, University College Dublin Veterinary Hospital, Belfield, Dublin 4, Ireland, Phone: +353 8604 33 088, E-mail:

出版信息

Vet Comp Orthop Traumatol. 2016 Sep 20;29(5):386-93. doi: 10.3415/VCOT-16-03-0041. Epub 2016 Jul 29.

Abstract

OBJECTIVES

To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints.

METHODS

Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast.

RESULTS

Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times.

LIMITATIONS

Safety and efficacy could not be established.

CLINICAL RELEVANCE

Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

摘要

目的

比较马骶髂关节颅侧(CR)和尾内侧(CM)超声引导注射时注射剂的准确性和分布情况。

方法

使用颅旁矢状面(CR;18号弯形、25厘米脊麻针)和尾内侧(CM;18号直形、15厘米脊麻针)超声引导方法,对10个腰骶骨盆标本的双侧骶髂关节进行注射。注射剂由4毫升碘化造影剂和2毫升亚甲蓝组成。注射前后进行计算机断层扫描(CT)。记录针引导和重新定位尝试的时间。分析CT序列以确定造影剂的准确性和分布情况。

结果

40次注射中有15次在骶髂关节内检测到关节内造影剂。CR和CM方法分别在17/20次和20/20次注射后,将注射剂注入距骶髂关节边缘≤2厘米处。CR方法中造影剂最接近骶髂关节的中位距离为0.4厘米(四分位间距[IQR]:1.5厘米),CM方法为0.6厘米(IQR:0.95厘米)。颅侧注射有15/20次导致注射剂接触腰骶椎间横突关节。尾内侧注射有16/20次位于血管周围。

局限性

无法确定安全性和有效性。

临床意义

针对骶髂关节的颅侧和CM超声引导注射在关节周围注射时非常准确,但关节内注射的准确性较差。经常发现注射剂与骶髂骨间韧带以及骶髂关节附近的神经血管和滑膜结构接触。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验