Pharmasan Labs, Inc., 373 280th Street, Osceola, WI 54020, USA.
Pharmasan Labs, Inc., 373 280th Street, Osceola, WI 54020, USA.
Talanta. 2016 Oct 1;159:238-247. doi: 10.1016/j.talanta.2016.06.032. Epub 2016 Jun 16.
It remains a challenge to simultaneously quantify catecholamines and metanephrines in a simple, sensitive and cost-effective manner due to pre-analytical and analytical constraints. Herein, we describe such a method consisting of a miniaturized sample preparation and selective LC-MS/MS detection by the use of second morning spot urine samples. Ten microliters of second morning urine sample were subjected to solid phase extraction on an Oasis HLB microplate upon complexation with phenylboronic acid. The analytes were well-resolved on a Luna PFP column followed by tandem mass spectrometric detection. Full validation and suitability of spot urine sampling and biological variation were investigated. The extraction recovery and matrix effect are 74.1-97.3% and 84.1-119.0%, respectively. The linearity range is 2.5-500, 0.5-500, 2.5-1250, 2.5-1250 and 0.5-1250ng/mL for norepinephrine, epinephrine, dopamine, normetanephrine and metanephrine, respectively. The intra- and inter-assay imprecisions are ≤9.4% for spiked quality control samples, and the respective recoveries are 97.2-112.5% and 95.9-104.0%. The Deming regression slope is 0.90-1.08, and the mean Bland-Altman percentage difference is from -3.29 to 11.85 between a published and proposed method (n=50). A correlation observed for the spot and 24h urine collections is significant (n=20, p<0.0001, r: 0.84-0.95, slope: 0.61-0.98). No statistical differences are found in day-to-day biological variability (n=20). Reference intervals are established for an apparently healthy population (n=88). The developed method, being practical, sensitive, reliable and cost-effective, is expected to set a new stage for routine testing, basic research and clinical applications.
由于分析前和分析上的限制,同时以简单、灵敏和具有成本效益的方式定量儿茶酚胺和甲氧基肾上腺素仍然是一个挑战。在此,我们描述了一种方法,该方法包括使用第二晨尿样本进行微型化样品制备和选择性 LC-MS/MS 检测。将 10μL 第二晨尿样品与苯硼酸络合后,在 Oasis HLB 微板上进行固相萃取。分析物在 Luna PFP 柱上得到很好的分离,然后进行串联质谱检测。对尿样点采集和生物变异性的充分验证和适用性进行了研究。提取回收率和基质效应分别为 74.1-97.3%和 84.1-119.0%。线性范围分别为去甲肾上腺素、肾上腺素、多巴胺、去甲变肾上腺素和甲氧基肾上腺素 2.5-500、0.5-500、2.5-1250、2.5-1250 和 0.5-1250ng/mL。对于加标质控样品,日内和日间精密度的不精密度均≤9.4%,各自的回收率为 97.2-112.5%和 95.9-104.0%。Deming 回归斜率为 0.90-1.08,与已发表方法(n=50)相比,平均 Bland-Altman 百分比差异在 -3.29 至 11.85 之间(n=50)。在 20 名受试者中观察到点尿和 24 小时尿收集之间的相关性具有显著性(n=20,p<0.0001,r:0.84-0.95,斜率:0.61-0.98)。在 20 名受试者中,日间生物变异性无统计学差异。为一个明显健康的人群建立了参考区间(n=88)。所开发的方法实用、灵敏、可靠且具有成本效益,有望为常规检测、基础研究和临床应用开辟新的阶段。