Abstract

A thermal dissociation cavity attenuated phase shift spectroscopy (TD-CAPS) instrument was developed for measuring total peroxy nitrates (PNs) and organic nitrates (ONs) concentrations in the clean atmosphere. This instrument is easy to operate and can be applied to continuous measurement of PNs and ONs. A continuously measurable system is convenient to perform observations, especially in remote areas. Three lines (NO2, PNs, and ONs lines) were used for thermal dissociation. The NO2 line contains a quartz tube that is not heated, while the PN and ON lines contain quartz tubes that are heated at 433 K and 633 K, respectively. The concentrations of NO2, NO2 + PNs, and NO2 + PNs + ONs can be obtained from the NO2, PN, and ON lines, respectively. The lower limit values of the detection limit (3σ) for PNs and ONs were estimated to be 21 parts per trillion by volume with an integration time of 2 min. PNs were selectively thermally decomposed in the PNs line and formed NO2 quantitatively. In the ONs line, both PNs and ONs were thermally decomposed to produce NO2 quantitatively, but partial decomposition of HNO3 at 633 K interfered with the ONs measurement. Therefore, a HNO3 scrubber is required before the ONs line. Continuous observations were conducted with the TD-CAPS instrument in a remote area, and the instrument performed well for obtaining PNs and ONs concentrations.

摘要

开发了一种热解离腔衰减相移光谱仪(TD-CAPS),用于测量清洁大气中总过氧硝酸盐(PNs)和有机硝酸盐(ONs)的浓度。该仪器操作简便,可用于PNs和ONs的连续测量。连续可测量系统便于进行观测,特别是在偏远地区。使用三条谱线(NO2、PNs和ONs谱线)进行热解离。NO2谱线包含一根未加热的石英管,而PN和ON谱线分别包含在433 K和633 K下加热的石英管。NO2、NO2 + PNs和NO2 + PNs + ONs的浓度可分别从NO2、PN和ON谱线中获得。PNs和ONs的检测限(3σ)下限值估计为21体积万亿分之一,积分时间为2分钟。PNs在PNs谱线中被选择性热分解并定量形成NO2。在ONs谱线中,PNs和ONs都被热分解以定量产生NO2,但633 K下HNO3的部分分解干扰了ONs的测量。因此,在ONs谱线之前需要一个HNO3洗涤器。使用TD-CAPS仪器在偏远地区进行了连续观测,该仪器在获取PNs和ONs浓度方面表现良好。