Suppr超能文献

对口腔内和口腔外可摘矫治器依从性的客观评估。

Objective assessment of compliance with intra- and extraoral removable appliances.

作者信息

Arreghini Angela, Trigila Silvia, Lombardo Luca, Siciliani Giuseppe

出版信息

Angle Orthod. 2017 Jan;87(1):88-95. doi: 10.2319/020616-104.1. Epub 2016 Aug 10.

Abstract

OBJECTIVE

To conduct an objective assessment of the level of compliance in young patients prescribed various types of removable appliances and to determine the influence of device type, treatment duration, and patient age, gender, psychological maturity, and awareness of monitoring on compliance.

MATERIALS AND METHODS

A total of 30 patients were fitted with either a class 2 (Frankel or bionator) or a class 3 (face mask) removable appliance, each bearing a compliance indicator chip, and they were instructed to wear them for 13 hours per day. Compliance was monitored by means of the sensor for an average of 8 months. Of the patients, 14 were informed that their appliance was fitted with a monitoring sensor, and 16 were not. The psychological maturity of all patients was assessed on the Nowicki-Strickland Locus of Control Scale, and the effect on compliance of this score as well as the patient- and treatment-related variables considered were determined via statistical analysis Results: The mean compliance recorded by the chips was 8.6 ± 2.9 hours, far lower than the 13 hours prescribed, and younger patients showed significantly greater compliance than adolescents (P < .01). However, no significant differences in compliance were found between intra- and extraoral appliances, and neither gender, psychological scores, treatment duration, nor awareness of being monitored had any significant effect.

CONCLUSIONS

Compliance is generally very poor in young patients, regardless of their gender and psychological maturity. Although awareness of monitoring does not appear to boost compliance, such systems may be a valuable means of providing a dentist with objective information regarding their patients' compliance.

摘要

目的

对使用各类可摘矫治器的年轻患者的依从性水平进行客观评估,并确定矫治器类型、治疗时长以及患者年龄、性别、心理成熟度和对监测的认知对依从性的影响。

材料与方法

总共30例患者佩戴了二类(Frankel矫治器或生物调节器)或三类(面罩)可摘矫治器,每个矫治器都带有一个依从性指示芯片,并被要求每天佩戴13小时。通过传感器平均监测8个月的依从性情况。其中14例患者被告知其矫治器装有监测传感器,16例患者未被告知。使用诺维茨基 - 斯特里克兰控制点量表评估所有患者的心理成熟度,并通过统计分析确定该分数以及所考虑的患者和治疗相关变量对依从性的影响。结果:芯片记录的平均依从性为8.6±2.9小时,远低于规定的13小时,年轻患者的依从性显著高于青少年(P<.01)。然而,口内和口外矫治器在依从性方面未发现显著差异,性别、心理得分、治疗时长以及对被监测的认知均未产生显著影响。

结论

年轻患者的依从性普遍很差,无论其性别和心理成熟度如何。尽管对监测的认知似乎并未提高依从性,但此类系统可能是为牙医提供有关患者依从性客观信息的宝贵手段。

相似文献

引用本文的文献

7
Wearable Orofacial Technology and Orthodontics.可穿戴口腔技术与正畸学
Dent J (Basel). 2023 Jan 10;11(1):24. doi: 10.3390/dj11010024.
9
Orthodontic Compliance Assessment: A Systematic Review.正畸依从性评估:系统评价。
Int Dent J. 2022 Oct;72(5):597-606. doi: 10.1016/j.identj.2022.07.004. Epub 2022 Aug 10.

本文引用的文献

6
Effects of wear time recording on the patient's compliance.佩戴时间记录对患者依从性的影响。
Angle Orthod. 2013 Nov;83(6):1002-8. doi: 10.2319/010913-25.1. Epub 2013 Apr 25.