Suppr超能文献

暴露于高剂量钴-60γ射线的人外周血淋巴细胞中,花萼海绵诱癌素A诱导的早熟染色体凝集多个参数的剂量反应。

Dose response of multiple parameters for calyculin A-induced premature chromosome condensation in human peripheral blood lymphocytes exposed to high doses of cobalt-60 gamma-rays.

作者信息

Lu Xue, Zhao Hua, Feng Jiang-Bin, Zhao Xiao-Tao, Chen De-Qing, Liu Qing-Jie

机构信息

China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, PR China.

Department of Cardiology, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, PR China.

出版信息

Mutat Res Genet Toxicol Environ Mutagen. 2016 Sep 1;807:47-54. doi: 10.1016/j.mrgentox.2016.06.010. Epub 2016 Jul 27.

Abstract

Many studies have investigated exposure biomarkers for high dose radiation. However, no systematic study on which biomarkers can be used in dose estimation through premature chromosome condensation (PCC) analysis has been conducted. The present study aims to screen the high-dose radiation exposure indicator in calyculin A-induced PCC. The dose response of multiple biological endpoints, including G2/A-PCC (G2/M and M/A-PCC) index, PCC ring (PCC-R), ratio of the longest/shortest length (L/L ratio), and length and width ratio of the longest chromosome (L/B ratio), were investigated in calyculin A-induced G2/A-PCC spreads in human peripheral blood lymphocytes exposed to 0-20Gy (dose-rate of 1Gy/min) cobalt-60 gamma-rays. The G2/A-PCC index was decreased with enhanced absorbed doses of 4-20Gy gamma-rays. The G2/A PCC-R at 0-12Gy gamma-rays conformed to Poisson distribution. Three types of PCC-R were scored according to their shape and their solidity or hollowness. The frequencies of hollow PCC-R and PCC-R including or excluding solid ring in G2/A-PCC spreads were enhanced with increased doses. The length and width of the longest chromosome, as well as the length of the shortest chromosome in each G2/M-PCC or M/A-PCC spread, were measured. All L/L or L/B ratios in G2/M-PCC or M/A-PCC spread increased with enhanced doses. A blind test with two new irradiated doses was conducted to validate which biomarker could be used in dose estimation. Results showed that hollow PCC-R and PCC-R including solid ring can be utilized for accurate dose estimation, and that hollow PCC-R was optimal for practical application.

摘要

许多研究已经对高剂量辐射的暴露生物标志物进行了调查。然而,尚未开展关于哪些生物标志物可用于通过早熟染色体浓缩(PCC)分析进行剂量估计的系统性研究。本研究旨在筛选在花萼海绵诱癌素A诱导的PCC中高剂量辐射暴露指标。在暴露于0 - 20Gy(剂量率为1Gy/分钟)钴-60γ射线的人外周血淋巴细胞中,对花萼海绵诱癌素A诱导的G2/A - PCC展开中多个生物学终点的剂量反应进行了研究,这些终点包括G2/A - PCC(G2/M和M/A - PCC)指数、PCC环(PCC - R)、最长/最短长度比(L/L比)以及最长染色体的长度与宽度比(L/B比)。随着γ射线吸收剂量从4Gy增加到20Gy,G2/A - PCC指数降低。0 - 12Gyγ射线照射下的G2/A PCC - R符合泊松分布。根据PCC - R的形状及其实心或空心程度对三种类型的PCC - R进行评分。随着剂量增加,G2/A - PCC展开中空心PCC - R以及包含或不包含实心环的PCC - R的频率增加。测量了每个G2/M - PCC或M/A - PCC展开中最长染色体的长度和宽度以及最短染色体的长度。G2/M - PCC或M/A - PCC展开中的所有L/L或L/B比均随剂量增加而增加。进行了一项包含两个新照射剂量的盲法试验,以验证哪些生物标志物可用于剂量估计。结果表明,空心PCC - R和包含实心环的PCC - R可用于准确的剂量估计,并且空心PCC - R在实际应用中是最佳的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验