The retention of 75Se-homotaurocholic acid (75SeHCAT) was measured in 12 healthy controls and in 21 patients with Crohn's disease and compared with the maximum postprandial rise in the serum concentration of cholylglycine (CG) in order to detect bile acid malabsorption. The retention of 75SeHCAT was lowered in all patients with inflammation or resection of the terminal ileum over a length more than 20 cm. In 64% of these patients bile acid malabsorption could also be detected by the absence of a significant rise of the postprandial CG serum level but only if the loss of the ileal function exceeded 30 cm. Although less sensitive than the 75SeHCAT retention, the CG method is simpler to apply in terms of laboratory technology and does not involve exposure to radioactivity. The CG method appears to be of use to detect bile acid malabsorption in certain cases. In the case of negatively if still bile acid malabsorption is suspected more sensitive tests such as 75SeHCAT retention should be carried out to further evaluate bile acid malabsorption.