Suppr超能文献

血浆羊毛甾醇作为回肠切除术后胆汁酸吸收不良的筛查试验:与75SeHCAT试验及粪便胆汁酸排泄的相关性

Plasma lathosterol as a screening test for bile acid malabsorption due to ileal resection: correlation with 75SeHCAT test and faecal bile acid excretion.

作者信息

Färkkilä M A, Kairemo K J, Taavitsainen M J, Strandberg T A, Miettinen T A

机构信息

Department of Medicine, University of Helsinki, Finland.

出版信息

Clin Sci (Lond). 1996 Apr;90(4):315-9. doi: 10.1042/cs0900315.

Abstract
  1. Plasma lathosterol concentration, known to reflect cholesterol and bile acid synthesis, was evaluated as a screening test for bile acid malabsorption, comparing it with faecal bile acid measurements, SeHCAT test and Schilling test in 22 subjects of whom six were healthy controls and 16 had Crohn's disease with ileal resections of varying length. 2. Plasma lathosterols and other non-cholesterol sterols were determined by GLC. Faecal bile acids were measured by GLC, and SeHCAT retention times by gamma camera. The study subjects were divided into two groups according to the degree of bile acid malabsorption: controls (faecal bile acids < 10 mg day-1 kg-1, n = 9) and bile acid malabsorption (faecal bile acids > 10 mg day-1 kg-1, n = 13). 3. Faecal bile acid excretion was 5.9 +/- 1.0 mg day-1 kg-1 in control subjects and 45.7 +/- 6.1 mg day-1 kg-1 in the bile acid malabsorption group. The biological half-life of 75SeHCAT (T1/2) was 95.6 +/- 16.3 h and 14.1 +/- 4.1 h, respectively. Plasma lathosterol levels were significantly elevated in patients with bile acid malabsorption (742 +/- 84 micrograms/ml compared with 400 +/- 59 micrograms/ml in control subjects) and correlated closely with faecal bile acid levels (r = 0.779, P < 0.001), with 75SeHCAT T1/2 (r = -0.524, P < 0.05) and with Schilling test (r = -0.591, P < 0.05). Significant correlations were also obtained for delta 8-cholestenol with faecal bile acids (r = 0.784, P < 0.001) and 75SeHCAT (r = -0.505, P < 0.05). The biological half-life of SeHCAT correlated with faecal bile acid excretion (r = -0.702, P < 0.001). Using mean+2 SD of lathosterol (In micrograms/ml cholesterol) as a cut-off value and 10 mg day-1 kg-1 as the upper limit for faecal bile acid excretion, the test gives 100% sensitivity and 82% specificity for plasma lathosterol determination to detect bile acid malabsorption. 4. The results indicate that both the 75SeHCAT test and plasma lathosterol detect bile acid malabsorption in patients with ileal resections for Crohn's disease. However, plasma lathosterol is a simpler and less expensive method.
摘要
  1. 血浆羊毛甾醇浓度已知可反映胆固醇和胆汁酸的合成,对其作为胆汁酸吸收不良的筛查试验进行了评估,在22名受试者中,将其与粪便胆汁酸测量、SeHCAT试验和希林试验进行比较,其中6名是健康对照者,16名患有克罗恩病且回肠切除长度各异。2. 血浆羊毛甾醇和其他非胆固醇甾醇通过气相色谱法测定。粪便胆汁酸通过气相色谱法测量,SeHCAT保留时间通过γ相机测定。根据胆汁酸吸收不良的程度将研究对象分为两组:对照组(粪便胆汁酸<10mg/天·kg⁻¹,n = 9)和胆汁酸吸收不良组(粪便胆汁酸>10mg/天·kg⁻¹,n = 13)。3. 对照组受试者的粪便胆汁酸排泄量为5.9±1.0mg/天·kg⁻¹,胆汁酸吸收不良组为45.7±6.1mg/天·kg⁻¹。⁷⁵SeHCAT的生物半衰期(T1/2)分别为95.6±16.3小时和14.1±4.1小时。胆汁酸吸收不良患者的血浆羊毛甾醇水平显著升高(742±84μg/ml,而对照组为400±59μg/ml),且与粪便胆汁酸水平密切相关(r = 0.779,P<0.001),与⁷⁵SeHCAT T1/2(r = -0.524,P<0.05)以及希林试验(r = -0.591,P<0.05)相关。δ8-胆甾烯醇与粪便胆汁酸(r = 0.784,P<0.001)和⁷⁵SeHCAT(r = -0.505,P<0.05)也有显著相关性。SeHCAT的生物半衰期与粪便胆汁酸排泄相关(r = -0.702,P<0.001)。以羊毛甾醇的均值+2标准差(以μg/ml胆固醇计)作为临界值,以10mg/天·kg⁻¹作为粪便胆汁酸排泄的上限,该试验在检测胆汁酸吸收不良时,血浆羊毛甾醇测定的灵敏度为100%,特异性为82%。4. 结果表明,⁷⁵SeHCAT试验和血浆羊毛甾醇均可检测克罗恩病回肠切除患者的胆汁酸吸收不良。然而,血浆羊毛甾醇是一种更简单且成本更低的方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验