Suppr超能文献

使用FlowTriever装置进行急性大面积肺栓塞的血栓清除术。

Clot Extraction With the FlowTriever Device in Acute Massive Pulmonary Embolism.

作者信息

Weinberg Aaron Samuel, Dohad Suhail, Ramzy Danny, Madyoon Hooman, Tapson Victor F

机构信息

1 Pulmonary and Critical Care, Cedars-Sinai Medical Center, Los Angeles, CA, USA.

2 Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA, USA.

出版信息

J Intensive Care Med. 2016 Dec;31(10):676-679. doi: 10.1177/0885066616666031. Epub 2016 Sep 21.

Abstract

Clinical guidelines support the use of systemic thrombolytic therapy for acute massive pulmonary embolism (PE). When anticoagulation and thrombolysis fail or are contraindicated, options become limited. We report an acute PE case in which treatment options were limited, and a novel device, the FlowTriever (Inari Medical, Irvine, California), was successfully used. This is the first case report of the use of this device that we are aware of.

摘要

临床指南支持对急性大面积肺栓塞(PE)使用全身溶栓治疗。当抗凝和溶栓治疗失败或存在禁忌证时,治疗选择就会变得有限。我们报告了一例急性PE病例,该病例的治疗选择有限,一种新型装置FlowTriever(加利福尼亚州欧文市的Inari Medical公司生产)被成功使用。据我们所知,这是首例使用该装置的病例报告。