Suppr超能文献

使用新型化学发光分析法测定临床及亚临床甲状腺功能亢进症中的促甲状腺激素

Measurement of thyrotropin in clinical and subclinical hyperthyroidism using a new chemiluminescent assay.

作者信息

Ross D S, Ardisson L J, Meskell M J

机构信息

Department of Medicine, Massachusetts General Hospital, Boston 02114.

出版信息

J Clin Endocrinol Metab. 1989 Sep;69(3):684-8. doi: 10.1210/jcem-69-3-684.

Abstract

A new commercially available chemiluminescent TSH assay demonstrates an 8- to 10-fold increase in sensitivity over a sensitive immunoradiometric assay, allowing increased ability to distinguish partial from more complete thyrotroph suppression. Sera were analyzed from 145 patients who had TSH concentrations below 0.08 mU/L in the immunoradiometric assay. Most patients with overt hyperthyroidism had undetectable TSH concentrations in the chemiluminescent assay. Three groups of patients were identified, in which a large subgroup had undetectable values in the immunoradiometric assay and detectable values in the chemiluminescent assay (12 of 17 patients under treatment for hyperthyroidism who had recently normalized their serum thyroid hormone levels, 33 of 68 patients taking L-T4, and 4 of 8 patients with endogenous subclinical hyperthyroidism). In addition, several patients with undetectable basal and detectable TRH-stimulated TSH values in the immunoradiometric assay had detectable basal TSH values in the chemiluminescent assay. The utility of first generation TSH immunometric assays was their ability to distinguish hyperthyroidism from euthyroidism. The clinical utility of increasingly sensitive TSH assays will be to distinguish degrees of thyrotroph suppression in subclinical hyperthyroidism.

摘要

一种新的市售化学发光促甲状腺激素(TSH)检测方法显示,其灵敏度比灵敏的免疫放射分析方法提高了8至10倍,从而增强了区分部分甲状腺激素抑制和更完全甲状腺激素抑制的能力。对145例在免疫放射分析中促甲状腺激素浓度低于0.08 mU/L的患者的血清进行了分析。大多数显性甲状腺功能亢进患者在化学发光检测中促甲状腺激素浓度检测不到。确定了三组患者,其中一大亚组在免疫放射分析中检测不到促甲状腺激素值,而在化学发光检测中可检测到促甲状腺激素值(17例正在接受甲状腺功能亢进治疗且血清甲状腺激素水平最近已恢复正常的患者中有12例,68例服用左甲状腺素(L-T4)的患者中有33例,以及8例内源性亚临床甲状腺功能亢进患者中有4例)。此外,在免疫放射分析中基础促甲状腺激素值检测不到但促甲状腺激素释放激素(TRH)刺激后促甲状腺激素值可检测到的几名患者,在化学发光检测中基础促甲状腺激素值可检测到。第一代促甲状腺激素免疫分析方法的作用是能够区分甲状腺功能亢进和甲状腺功能正常。越来越灵敏的促甲状腺激素检测方法的临床作用将是区分亚临床甲状腺功能亢进中甲状腺激素抑制的程度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验