Many studies reported for estimating serum YKL-40 using ELISA or RIA methods. This study introduces the plausible utilization of real-time surface plasmon resonance (SPR) technology in investigating the expression of serum YKL-40 protein levels and ELISA method for serum IgE in bronchial asthma.
A commercially available BIAcore 2000 instrument, based on SPR technology, was utilized for assessing serum YKL-40 levels in a control sample size of 45 and active sample size of 97. Antibody immobilization was optimized to obtain the best sensor performance and a sensitive analytic detection. A commercially available ELISA kit was utilized for detecting serum IgE to estimate allergic condition-associated asthma.
The results of SPR technology could distinctly classify with highly statistical significance, the asthma severities by estimating the elevated levels of YKL-40 in blood sera of minute quantities (up to 0.33 ng/ml), and thus differentiates superior utility in comparison with ELISA method. No statistically significant correlation of YKL-40 and IgE was observed.
Serum YKL-40 may be used as a protein marker in classifying asthma severity by applying SPR technology as a reliable, label-free, highly sensitive, and cost-effective tool.
许多研究报道了使用酶联免疫吸附测定(ELISA)或放射免疫分析(RIA)方法来估计血清YKL-40。本研究介绍了实时表面等离子体共振(SPR)技术在研究血清YKL-40蛋白水平表达以及支气管哮喘患者血清IgE的ELISA方法中的合理应用。
使用基于SPR技术的市售BIAcore 2000仪器,对45例对照样本和97例活性样本进行血清YKL-40水平评估。优化抗体固定以获得最佳传感器性能和灵敏的分析检测。使用市售ELISA试剂盒检测血清IgE以评估与过敏相关的哮喘。
SPR技术的结果能够以高度统计学意义清晰地对哮喘严重程度进行分类,通过估计微量血清(高达0.33 ng/ml)中YKL-40水平的升高来实现,因此与ELISA方法相比具有更高的实用性。未观察到YKL-40与IgE之间具有统计学意义的相关性。
通过将SPR技术作为一种可靠、无标记、高度灵敏且经济高效的工具,血清YKL-40可作为哮喘严重程度分类的蛋白质标志物。