School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI, USA.
Departments of Internal Medicine and Radiology, Medical School, University of Michigan, Ann Arbor, MI, USA.
J Nucl Cardiol. 2018 Feb;25(1):234-239. doi: 10.1007/s12350-016-0667-0. Epub 2016 Sep 15.
Regadenoson is a novel pharmacological stress agent whose disposition during hemodialysis is not known. The purpose of this study was to determine the clearance of regadenoson under varying dialytic conditions using an in vitro hemodialysis model.
Whole human blood was used to analyze the effect of hemodialysis on the clearance of regadenoson. Regadenoson transmembrane clearance (CL) was assessed for both a standard permeability and a high permeability polysulfone hemodialyzer with blood/dialysate flow rates of 300/600 and 400/800 mL/min. A two-tailed, paired Student's t test was used to compare regadenoson CL between hemodialyzer types and flow rates. The mean ± SD regadenoson CL values ranged between 62.5 ± 11.8 and 89.1 ± 24.0 mL/min for all dialytic conditions. There was no significant difference in regadenoson CL between hemodialyzer types and flow rates (p > .05).
Hemodialysis enhances the clearance of regadenoson independent of hemodialyzer permeability and blood/dialysate flow rate. This clearance is modest relative to total body clearance and is unlikely to produce a clinically significant outcome.
雷卡弹是一种新型的药理学应激剂,其在血液透析过程中的分布情况尚不清楚。本研究的目的是使用体外血液透析模型来确定在不同透析条件下雷卡弹的清除率。
使用全人血来分析血液透析对雷卡弹清除率的影响。评估了标准通透性和高通透性聚砜血液透析器对雷卡弹跨膜清除率(CL)的影响,血液/透析液流速分别为 300/600 和 400/800mL/min。采用双尾配对学生 t 检验比较两种血液透析器类型和流速之间的雷卡弹 CL。所有透析条件下,雷卡弹 CL 的平均值 ± 标准差范围在 62.5 ± 11.8 和 89.1 ± 24.0mL/min 之间。血液透析器类型和流速对雷卡弹 CL 无显著差异(p>.05)。
血液透析可增强雷卡弹的清除率,而与血液透析器的通透性和血液/透析液流速无关。这种清除率与全身清除率相比适度,不太可能产生临床显著的结果。