肌肉近红外光谱信号与骨骼肌静脉血血红蛋白氧饱和度的比较。

Muscle Near-Infrared Spectroscopy Signals versus Venous Blood Hemoglobin Oxygen Saturation in Skeletal Muscle.

机构信息

1School of Kinesiology, Auburn University, Auburn, AL; 2Key Laboratory of Adolescent Health Assessment and Exercise Intervention, Ministry of Education, East China Normal University, Shanghai, CHINA; 3College of Applied Health Sciences, University of Illinois at Chicago, Chicago, IL; 4Department of Health and Human Performance, University of Wisconsin-Platteville, Platteville, WI.

出版信息

Med Sci Sports Exerc. 2016 Oct;48(10):2013-20. doi: 10.1249/MSS.0000000000001001.

Abstract

PURPOSE

The study aimed to examine the relationship between near-infrared spectroscopy (NIRS) signals and venous hemoglobin oxygen saturation (O2Hb%) and venous oxygen concentration (CvO2).

METHODS

Gastrocnemius muscles (GS) in six dogs were surgically isolated and pump perfused. NIRS signals were recorded, and venous blood samples were collected at constant flow rates (control flow, high flow, and low flow) at rest as well as during electrically stimulated tetanic muscle contractions at rates of one contraction per 2 s (1/2 s) and two contractions per 3 s (2/3 s). Similar data were also collected at three different inspired O2 percentages (12%, 21%, and 100%) with constant blood flow.

RESULTS

Complete data from five animals were analyzed; all data from one animal were deleted because of erratic oxy-NIRS signals. Venous O2Hb% ranged from 7.6% to 97.5% across the various experimental conditions. After the NIRS signals were normalized to the physiological range, a high linear correlation was seen between the deoxygenated heme signal (HHbMb%) and the venous O2Hb% (R = 0.92 ± 0.05), between the oxygenated heme signal (HbMbO2%) and the venous O2Hb% (R = 0.92 ± 0.03), between the HHbMb% and the CvO2 (R = 0.89 ± 0.06), and between the HbMbO2% and the CvO2 (R = 0.90 ± 0.05). The overall relationships between HHbMb%, HbMbO2%, and venous O2Hb% as well as between HHbMb%, HbMbO2%, and CvO2 were also linear and highly correlated with R values ranging from 0.81 to 0.90.

CONCLUSION

In this controlled canine muscle model, NIRS signals are highly correlated with venous O2Hb% and CvO2 across a wide range of physiological conditions. The practical application of our results is that for an individual muscle or perhaps muscle group, normalized NIRS HHbMb and HbMbO2 signals accurately reflect the mean venous O2 saturation of the interrogated muscle tissue.

摘要

目的

本研究旨在探讨近红外光谱(NIRS)信号与静脉血红蛋白氧饱和度(O2Hb%)和静脉氧浓度(CvO2)之间的关系。

方法

对 6 只狗的腓肠肌进行手术隔离和泵灌注。在休息时以及以每 2 秒(1/2 秒)和每 3 秒(2/3 秒)一次的电刺激强直肌肉收缩率下,以恒定流量(对照流量、高流量和低流量)记录 NIRS 信号并采集静脉血样本。在恒定血流量下,还在三个不同的吸入氧气百分比(12%、21%和 100%)下收集类似的数据。

结果

对五只动物的完整数据进行了分析;由于氧-NIRS 信号不稳定,一只动物的所有数据均被删除。在各种实验条件下,静脉 O2Hb% 范围为 7.6%至 97.5%。在将 NIRS 信号归一化为生理范围后,去氧血红素信号(HHbMb%)与静脉 O2Hb%之间存在高度线性相关(R=0.92±0.05),氧合血红素信号(HbMbO2%)与静脉 O2Hb%之间存在高度线性相关(R=0.92±0.03),HHbMb%与 CvO2 之间存在高度线性相关(R=0.89±0.06),HbMbO2%与 CvO2 之间存在高度线性相关(R=0.90±0.05)。HHbMb%、HbMbO2%与静脉 O2Hb%以及 HHbMb%、HbMbO2%与 CvO2 之间的总体关系也是线性的,相关系数 R 值在 0.81 到 0.90 之间。

结论

在这个受控制的犬肌肉模型中,NIRS 信号与静脉 O2Hb%和 CvO2 在广泛的生理条件下高度相关。我们研究结果的实际应用是,对于单个肌肉或肌肉群,归一化的 NIRS HHbMb 和 HbMbO2 信号可以准确反映被检测肌肉组织的平均静脉氧饱和度。