多发性硬化症中的寡克隆带和IgG指数:用途与局限性

Oligoclonal bands and the IgG index in multiple sclerosis: uses and limitations.

作者信息

Giles P D, Heath J P, Wroe S J

机构信息

Department of Clinical Chemistry, Royal Infirmary, Edinburgh, UK.

出版信息

Ann Clin Biochem. 1989 Jul;26 ( Pt 4):1317-23.

PMID:2764482
Abstract

The relationship between two tests commonly used in the investigation of multiple sclerosis (MS), the IgG index and oligoclonal bands, has been assessed. Using an immunoblotting technique specific for IgG, analysis of cerebrospinal fluid for oligoclonal bands was found to provide greater diagnostic sensitivity than the IgG index without any loss of specificity. In patients without oligoclonal bands the IgG index had no diagnostic value for MS and in the presence of bands the magnitude of the index was unrelated to the clinical certainty of the diagnosis. High values of the IgG index were invariably associated with the presence of oligoclonal bands and the IgG index appeared to have no clinical significance independent of this relationship. Even as a screening test the IgG index has serious limitations.

摘要

多发性硬化症(MS)研究中常用的两项检测指标——IgG指数和寡克隆带之间的关系已得到评估。采用针对IgG的免疫印迹技术,发现对脑脊液进行寡克隆带分析比IgG指数具有更高的诊断敏感性,且特异性无任何损失。在无寡克隆带的患者中,IgG指数对MS无诊断价值;而在有寡克隆带的情况下,该指数的大小与诊断的临床确定性无关。IgG指数高值总是与寡克隆带的存在相关,且IgG指数似乎独立于这种关系之外并无临床意义。即便作为一项筛查检测,IgG指数也存在严重局限性。