Abstract

Homograft implantation in the aortic position was a common approach for full root aortic surgical procedures in the early 2000s. Reintervention after degeneration of such homografts remains a challenge. We report two cases of successful implantation of the Edwards Intuity Elite rapid deployment valve into patients with degeneration of existing aortic homograft implants leading to severe aortic regurgitation.

摘要

在21世纪初,主动脉位置的同种异体移植植入术是全主动脉根部手术的常用方法。此类同种异体移植物退变后的再次干预仍然是一项挑战。我们报告了两例成功将爱德华兹Intuity Elite快速部署瓣膜植入现有主动脉同种异体移植植入物退变导致严重主动脉瓣反流患者的病例。