Ağladıoğlu Kadir, Akkaya Nuray, Güngör Harun R, Akkaya Semih, Ök Nusret, Özçakar Levent
Department of Radiology, Pamukkale University Medical School, Denizli, Turkey.
Department of Physical and Rehabilitation Medicine, Pamukkale University Medical School, Denizli, Turkey
J Ultrasound Med. 2016 Nov;35(11):2431-2438. doi: 10.7863/ultra.15.11050. Epub 2016 Sep 23.
The aim of this study was to explore the sonographic and elastographic properties of patellar and Achilles tendons in smoking and nonsmoking otherwise healthy adults.
We conducted a level 3 case-control analytical study. Smoking and nonsmoking volunteers (>18 years) without musculoskeletal system disorders were included in the study. Demographic characteristics and smoking habits (pack-years) were recorded. Proximal, middle, and distal third thicknesses of the patellar and Achilles tendons were measured by B-mode sonography. Strain ratio measurements of the same regions were measured by real-time ultrasound elastography.
A total of 69 participants (57 male and 12 female; mean age ± SD, 35.5 ± 7.8 years) were evaluated in the study. Smoking (n = 35) and nonsmoking (n = 34) groups had no significant differences in terms of age, body mass index, sex, and activity level (all P > .05). Proximal, middle, and distal thirds of the patellar and Achilles tendons were significantly thinner in the smoking group (all P < .05). Furthermore, strain ratio measurements in the same regions were significantly lower in the smoking group (all P< .05). Patellar tendon thicknesses and strain ratios had negative correlations with the smoking amount (all P < .05).
Thickness and strain ratio measurements of patellar and Achilles tendons were reduced (thinner and harder tendons) in smokers. Clinical implications of these morphologic and elastographic changes should be investigated in future studies.
本研究旨在探讨吸烟和不吸烟的健康成年人髌腱和跟腱的超声及弹性成像特征。
我们进行了一项3级病例对照分析研究。纳入了无肌肉骨骼系统疾病的吸烟和不吸烟志愿者(>18岁)。记录人口统计学特征和吸烟习惯(包年数)。通过B型超声测量髌腱和跟腱的近端、中间和远端三分之一处的厚度。通过实时超声弹性成像测量相同区域的应变率。
本研究共评估了69名参与者(57名男性和12名女性;平均年龄±标准差,35.5±7.8岁)。吸烟组(n = 35)和非吸烟组(n = 34)在年龄、体重指数、性别和活动水平方面无显著差异(所有P>.05)。吸烟组髌腱和跟腱的近端、中间和远端三分之一处明显更薄(所有P<.05)。此外,吸烟组相同区域的应变率测量值明显更低(所有P<.05)。髌腱厚度和应变率与吸烟量呈负相关(所有P<.05)。
吸烟者髌腱和跟腱的厚度及应变率测量值降低(肌腱更薄且更硬)。这些形态学和弹性成像变化的临床意义应在未来研究中进行探究。