Suppr超能文献

超声测量的血管血流动力学参数能否通过磁共振成像重现?

Are Sonographically Measured Vascular Haemodynamic Parameters Reproducible Using Magnetic Resonance Imaging?

作者信息

Rudolphi P B, Recke A, Langan E A, Hunold P, Kahle B K

机构信息

Department of Dermatology, University of Lübeck, Lübeck, Germany.

Department of Dermatology and Comprehensive Centre for Inflammation Medicine, University of Lübeck, Lübeck, Germany.

出版信息

Eur J Vasc Endovasc Surg. 2016 Nov;52(5):665-672. doi: 10.1016/j.ejvs.2016.08.004. Epub 2016 Sep 27.

Abstract

OBJECTIVE/BACKGROUND: Hemodynamic measurements of blood flow in the common femoral vein and artery can be performed readily using duplex sonography. The ratio of venous to arterial volume flow in these vessels, the venous arterial flow index (VAFI), is increased in patients with varicose veins and/or chronic venous disease. The objective was to determine the reproducibility of sonographically measured hemodynamic flow parameters using phase contrast magnetic resonance imaging (MRI).

METHODS

Based on hemodynamic volume flow measurements from the common femoral vein and artery the VAFI was calculated in seven patients with varicose veins (C2, Ep, As, Pr) and 32 healthy controls using standard duplex sonography and MRI.

RESULTS

Based on duplex sonography, the average VAFI (VAFI) was 1.05 ± 0.17. The same ratio, using MRI (VAFI_) was 1.05 ± 0.19. There was a significant correlation between the VAFI and the VAFI_ (p = .0021). In patients with venous disease, the average VAFI and VAFI_ were 1.36 ± 0.21 and 1.36 ± 0.20, respectively. In contrast, in the healthy cohort the VAFI was 1.00 ± 0.12 and the VAFI_ measured 1.01 ± 0.15. As expected, there was a significant difference between the VAFI measured in those with venous disease when compared with that of healthy controls (p < .0001).

CONCLUSION

There is a significant correlation between the VAFI measured using sonography and MRI. The study confirmed the elevation of VAFI in patients with chronic venous disease.

摘要

目的/背景:使用双功超声检查可轻松测量股总静脉和动脉中的血流动力学情况。在患有静脉曲张和/或慢性静脉疾病的患者中,这些血管的静脉与动脉体积流量之比,即静脉动脉血流指数(VAFI)会升高。目的是确定使用相位对比磁共振成像(MRI)进行超声测量的血流动力学参数的可重复性。

方法

基于股总静脉和动脉的血流动力学体积流量测量结果,使用标准双功超声检查和MRI计算7例静脉曲张患者(C2、Ep、As、Pr)和32名健康对照者的VAFI。

结果

基于双功超声检查,平均VAFI(VAFI)为1.05±0.17。使用MRI时,相同比例(VAFI_)为1.05±0.19。VAFI与VAFI_之间存在显著相关性(p = 0.0021)。在患有静脉疾病的患者中,平均VAFI和VAFI_分别为1.36±0.21和1.36±0.20。相比之下,在健康队列中,VAFI为1.00±0.12,VAFI_为1.01±0.15。正如预期的那样,患有静脉疾病者的VAFI与健康对照者相比存在显著差异(p < 0.0001)。

结论

超声检查和MRI测量的VAFI之间存在显著相关性。该研究证实了慢性静脉疾病患者的VAFI升高。