Accuracy of MEG in localizing irritative zone and seizure onset zone: Quantitative comparison between MEG and intracranial EEG.

作者信息

Kim Daeyoung, Joo Eun Yeon, Seo Dae-Won, Kim Min-Young, Lee Yong-Ho, Kwon Hyuk Chan, Kim Jae-Moon, Hong Seung Bong

机构信息

Department of Neurology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Republic of Korea.

Department of Neurology, Samsung Medical Center, Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.

出版信息

Epilepsy Res. 2016 Nov;127:291-301. doi: 10.1016/j.eplepsyres.2016.08.013. Epub 2016 Aug 16.

Abstract

BACKGROUND

We conducted the study to examine accuracy of the magnetoencephalography (MEG) spike source localization in presurgical evaluation of patients with medically refractory focal epilepsy.

METHODS

Ten consecutive patients with refractory focal epilepsy who were candidates for two-stage surgery with long-term intracranial electroencephalography (ICEEG) monitoring were enrolled. Interictal MEG recordings with simultaneous scalp EEG were obtained within 7days before the ICEEG electrode implantation. The location of each MEG spike source was quantitatively compared with ICEEG spike foci (focal area of interictal spikes) and ICEEG ictal foci (earliest cortical origin of seizures). Gyral-width concordance and sublobar concordance were also determined for all MEG spike sources. Gyral-width concordance was defined by distance of 15mm or less between MEG spike sources and ICEEG spike foci or ICEEG ictal foci.

RESULTS

Visual analyses of the MEG traces of all 10 patients revealed 292 spikes (29.2±24.0 per patient). Spike yield of the MEG was similar to the simultaneously recorded scalp EEG. MEG spike sources were closely located with ICEEG spike foci (distance: 9.3±10.8mm). Clustered MEG spike sources were even closer to ICEEG spike foci (distance: 7.3±6.4mm). MEG spike sources, even clustered ones, were less concordant with ICEEG ictal foci and had significant longer distance from ICEEG ictal foci (distance: 21.5±15.6mm for all sources, 19.7±13.7mm for clustered sources). Gyral-width concordance rate and sublobar concordance rate were also higher with ICEEG interictal spike foci than with ICEEG ictal foci. On the other hand, 53.4% of interictal spike foci from ICEEG were not detected by interictal MEG recordings.

CONCLUSIONS

MEG spike sources, especially clustered ones, from interictal recording could localize the irritative zone of ICEEG with a high accuracy. However, MEG spike sources have relatively poor correlation with seizure onset zone and lower sensitivity in identifying all irritative zones of ICEEG. This limitation should be considered in the interpretation of MEG results.

摘要

背景

我们开展这项研究以检验在药物难治性局灶性癫痫患者的术前评估中,脑磁图(MEG)棘波源定位的准确性。

方法

连续纳入10例难治性局灶性癫痫患者,这些患者均为接受长期颅内脑电图(ICEEG)监测的两阶段手术的候选者。在ICEEG电极植入前7天内,同时记录头皮脑电图并进行发作间期MEG记录。将每个MEG棘波源的位置与ICEEG棘波灶(发作间期棘波的局灶区域)和ICEEG发作起始灶(癫痫发作最早的皮质起源)进行定量比较。还确定了所有MEG棘波源的脑回宽度一致性和脑叶下一致性。脑回宽度一致性定义为MEG棘波源与ICEEG棘波灶或ICEEG发作起始灶之间的距离在15mm或更小。

结果

对所有10例患者的MEG轨迹进行视觉分析,共发现292个棘波(每位患者29.2±24.0个)。MEG的棘波产生率与同时记录的头皮脑电图相似。MEG棘波源与ICEEG棘波灶位置紧密(距离:9.3±10.8mm)。成簇的MEG棘波源与ICEEG棘波灶距离更近(距离:7.3±6.4mm)。MEG棘波源,即使是成簇的,与ICEEG发作起始灶的一致性较差,且与ICEEG发作起始灶的距离显著更长(所有源的距离:21.5±15.6mm,成簇源的距离:19.7±13.7mm)。脑回宽度一致性率和脑叶下一致性率在ICEEG发作间期棘波灶处也高于ICEEG发作起始灶处。另一方面,ICEEG发作间期棘波灶中有53.4%未被发作间期MEG记录检测到。

结论

发作间期记录的MEG棘波源,尤其是成簇的棘波源,能够高精度地定位ICEEG的刺激区。然而,MEG棘波源与癫痫发作起始区的相关性相对较差,在识别ICEEG的所有刺激区方面敏感性较低。在解释MEG结果时应考虑到这一局限性。