Kes Petar, Janssens Michiel Etienne, Bašić-Jukić Nikolina, Kljak Milića
Department of Nephrology, Arterial Hypertension, Dialysis and Kidney Transplantation, University Hospital Centre Zagreb, and Faculty of Medicine, University of Zagreb, Zagreb, Croatia.
Terumo BCT Europe NV, Zaventem, Belgium.
Transfusion. 2016 Dec;56(12):3065-3072. doi: 10.1111/trf.13850. Epub 2016 Oct 5.
Therapeutic plasma exchange (TPE) can be performed either on a membrane-based system (mTPE) or on a device that separates blood components by centrifugation (cTPE). The number of studies in this field is limited. This randomized study is the first that offers data on the membrane-based Diapact device (B. Braun Medical, Inc.) for TPE procedures and compares it to the centrifuge-based Spectra Optia (Terumo BCT, Inc.).
Twenty-seven patients were enrolled in this randomized prospective head-to-head study comparing the mTPE and cTPE systems. Procedures on both devices were standardized and the plasma removal efficiency (PRE); total procedure time (including setup and priming time); and removal efficiencies of blood cells, immunoglobulin (Ig)G, and fibrinogen for all procedures were analyzed.
While both systems removed similar amounts of plasma, it took the cTPE device a mean of 101.5 ± 24.6 minutes to finalize a procedure that was one-third less than procedures on the mTPE device (157 ± 26.2 min; p < 0.0001), due to a difference in PRE between the Spectra Optia (83.0% ± 4.9%) and the Diapact (53.2% ± 6.6%; p < 0.0001). The difference in removal efficiencies of IgG and blood cells were not significantly different but the Spectra Optia was more efficient in removing the larger fibrinogen protein than the Diapact (72.3% ± 8.5% vs. 62.9% ± 16.1%, respectively; p < 0.02).
This study shows that, although both systems perform adequate and safe TPE procedures, those on the Spectra Optia in comparison to the Diapact are more efficient in terms of plasma removal and significantly shorter.
治疗性血浆置换(TPE)可通过基于膜的系统(mTPE)或通过离心分离血液成分的设备(cTPE)进行。该领域的研究数量有限。这项随机研究是第一项提供基于膜的Diapact设备(贝朗医疗公司)用于TPE程序的数据,并将其与基于离心机的Spectra Optia(泰尔茂BCT公司)进行比较的研究。
27名患者参加了这项比较mTPE和cTPE系统的随机前瞻性对照研究。两种设备的操作均标准化,并分析了血浆清除效率(PRE)、总操作时间(包括设置和预充时间)以及所有操作中血细胞、免疫球蛋白(Ig)G和纤维蛋白原的清除效率。
虽然两种系统清除的血浆量相似,但cTPE设备完成一次操作的平均时间为101.5±24.6分钟,比mTPE设备的操作时间少三分之一(157±26.2分钟;p<0.0001),这是由于Spectra Optia(83.0%±4.9%)和Diapact(53.2%±6.6%;p<0.0001)之间的PRE存在差异。IgG和血细胞清除效率的差异无统计学意义,但Spectra Optia在清除较大的纤维蛋白原蛋白方面比Diapact更有效(分别为72.3%±8.5%和62.9%±16.1%;p<0.02)。
本研究表明,虽然两种系统都能进行充分且安全的TPE程序,但与Diapact相比,Spectra Optia在血浆清除方面更高效,且操作时间显著更短。