Scherr Carlos, de Carvalho Antonio Carlos, Belem Luciano Juaçaba, Loyola Luiz Henrique, Guerra Renata Leborato, Blanco Fernanda, Mangia Claudio
Fundação Procoração, Brazil; Instituto Nacional de Cardiologia, Brazil.
Fundação Procoração, Brazil; Universidade Federal do Rio de Janeiro, Brazil.
Int J Cardiol. 2016 Dec 15;225:123-127. doi: 10.1016/j.ijcard.2016.08.321. Epub 2016 Sep 17.
The increasing use of conducted electronic weapons (CEW) cause concern regarding its secure application, specially regarding the implications in the cardiovascular system.
The objective was to determine Spark CEW safety through cardiovascular parameters analysis of healthy volunteers subjected to its use.
Volunteers over 18years without cardiovascular disease or recent use of illegal drugs were submitted, before and after being affected with Spark CEW, to clinical evaluation; blood collection for serum laboratory tests; transthoracic electrocardiography at rest, transthoracic echodopplercardiogram and 24hour Holter.
All 71 patients reported being incapable of any voluntary reaction during the shock of the application time. No arrhythmia or myocardial necrosis was related to the use of non-lethal weapon SPARK. Reported adverse events were self-limited, and mostly mild.
SPARK brand CEW is effective in incapacitating individuals by the shock of the application time, without causing.
传导电子武器(CEW)的使用日益增加,引发了对其安全应用的关注,特别是关于对心血管系统的影响。
目的是通过对使用过Spark CEW的健康志愿者进行心血管参数分析来确定Spark CEW的安全性。
18岁以上无心血管疾病或近期未使用非法药物的志愿者在受到Spark CEW影响之前和之后接受了临床评估;采集血液进行血清实验室检测;静息状态下的经胸心电图、经胸超声心动图和24小时动态心电图。
所有71名患者均报告在电击施加期间无法做出任何自主反应。未发现心律失常或心肌坏死与使用非致命武器SPARK有关。报告的不良事件为自限性,且大多为轻度。
Spark品牌的CEW在电击施加期间能有效使人丧失能力,而不会造成……(原文此处不完整)