[Initial experiences with a novel nerve stimulator for use in axillary plexus anesthesia].

作者信息

Bachmann-M B, Biscoping J, Hempelmann G

机构信息

Abteilung für Anaesthesiologie und Operative Intensivmedizin, Klinikum der Justus-Liebig-Universität Giessen.

出版信息

Reg Anaesth. 1989 Jul;12(4):80-3.

PMID:2772278
Abstract

The advantages of an electrical nerve stimulator for detection of the axillary neurovascular sheath have been frequently described in the literature and are now well known. In most of these techniques, stimulation is achieved by a fixed electrical voltage and variable amplification. The new nerve stimulator presented here offers the possibility of measuring the current at the site of stimulation ("test" position). PATIENTS AND METHODS. Axillary block was performed in 23 patients undergoing orthopedic surgery. Identification of the neurovascular sheath was first achieved by the "loss of resistance" technique, after which the injection cannula was connected to the new device. Stimulation was started at 1.0 mA. In case of a negative response to stimulation the actual electric current was checked by means of the test position in order to exclude an error in the circuit system. In these cases, the position of the cannula was altered so as to maintain a response at the lowest possible current (less than 0.5 mA). After removal of the inner solid steel stylet of the cannula, the local anesthetic was injected while compressing the distal part of the neurovascular sheath in order to avoid downstream diffusion. RESULTS. All 23 patients were operated upon under axillary block after nerve stimulator control without any additional drugs. Table 2 indicates the lowest stimulation current that still evoked a response. Disturbances in the circuit system were found twice, one caused by a short circuit, the other by a desiccated gel pad on the adhesive electrode. After elimination of the defect, stimulation produced a response. DISCUSSION. Since it is now well known that induction of paresthesias in locating peripheral nerves can cause irreversible lesions, the use of electrical nerve stimulators is preferred to locate the cannula as near as possible to the nerve without direct contact. The mode of operation of the stimulator presented here, which defines the chosen technical starting impulse as well as the actual current, allows much better localization of nerves during local anesthesia. Thus, disturbances in the circuit between nerve stimulator and patient, as shown in the two cases, can be detected. According to our experience, the intensity of stimulation for successful nerve blockade should be approximately 0.5 mA or lower. Consequently, universally applicable stimulating instruments with constant electrical tension should allow fine tuning of the current in 0.1-mA aliquots.

摘要

相似文献

1
[Initial experiences with a novel nerve stimulator for use in axillary plexus anesthesia].
Reg Anaesth. 1989 Jul;12(4):80-3.
2
[In electric nerve stimulation can the distance from the nerves be inferred from the intensity of muscle contraction? Possible parameters and sources of error].[在电神经刺激中,能否根据肌肉收缩强度推断神经距离?可能的参数和误差来源]
Reg Anaesth. 1990 Sep;13(7):179-85.
3
Brachial plexus block with the nerve stimulator: motor response characteristics at three sites.使用神经刺激器进行臂丛神经阻滞:三个部位的运动反应特征
Reg Anesth. 1992 Sep-Oct;17(5):295-9.
4
[Brachial plexus block with a nerve stimulator and "around the needle" catheter technique].
Masui. 1993 May;42(5):761-4.
5
Using the nerve stimulator for peripheral or plexus nerve blocks.使用神经刺激器进行外周或神经丛神经阻滞。
Minerva Anestesiol. 2006 Jun;72(6):467-71.
6
[Relevance of nerve blocks in treating and diagnosing low back pain--is the quality decisive?].[神经阻滞在治疗和诊断腰背痛中的相关性——质量起决定性作用吗?]
Schmerz. 2001 Dec;15(6):474-83. doi: 10.1007/s004820100035.
7
[Low minimal stimulating current improves infraclavicular brachial plexus block efficacy].
Zhonghua Yi Xue Za Zhi. 2007 Jun 5;87(21):1470-3.
8
Efficacy of ultrasound-guided axillary brachial plexus block: a comparative study with nerve stimulator-guided method.超声引导下腋路臂丛神经阻滞的疗效:与神经刺激器引导法的对比研究
Chang Gung Med J. 2005 Jun;28(6):396-402.
9
Supraclavicular brachial plexus block with the aid of a nerve stimulator.
Acta Anaesthesiol Belg. 1984 Mar;35(1):5-17.
10
[Axillary blockade of the brachial plexus. A prospective evaluation of 1133 cases of plexus catheter anesthesia].[臂丛神经腋路阻滞。1133例臂丛神经导管麻醉的前瞻性评估]
Reg Anaesth. 1988 Jan;11(1):7-11.

引用本文的文献

1
Corrosion and Ion Release in 304L Stainless Steel Biomedical Stylets.304L不锈钢生物医学探针的腐蚀与离子释放
Materials (Basel). 2025 Aug 11;18(16):3769. doi: 10.3390/ma18163769.