Wang Juan, Wu Nan, Yang Yaling
Faculty of Life Science and Technology, Kunming University of Science and Technology, Kunming 650500, China.
Kunming Energy Conservation Supervision Team, Kunming 650031, China.
J Chromatogr Sci. 2016 Nov;54(10):1834-1840. doi: 10.1093/chromsci/bmw130. Epub 2016 Oct 12.
A vortex-assisted hollow fiber liquid-phase microextraction method using a mixed solvent as the extraction solvent followed by high performance liquid chromatography diode-array detection was developed for the extraction and determination of two carotenoids including lutein and β-carotene from egg yolk. The method is based on the microextraction of carotenoids from sample solution into extracting agent (20 μL), which is located in the lumen of hollow fiber followed by vortex-mixing. The mixed solvent (1-octanol+1-undecanol, 6:4, v:v) was employed as extracting agent for it has suitable viscosity and compatible with carotenoids via hollow fiber. Vortex-mixing was utilized to provide effective and mild mixing of sample solution and increase the contact between analytes and boundary layers of the hollow fiber. Parameters influencing recoveries were investigated and optimized. Under the optimum conditions, the linear range of lutein and β-carotene were from 50 to 1,000 ng mL The correlation coefficients of the calibration curves were >0.9982, relative standard deviations (n = 5) were between 2.23% and 3.51% and the limits of detection were 0.038 and 0.045 μg mL for lutein and β-carotene, respectively. The proposed method was successfully applied to the extraction and determination of caroteonids in egg yolk with the satisfactory relative recoveries (90.2-101.8%).
建立了一种涡旋辅助中空纤维液相微萃取方法,该方法使用混合溶剂作为萃取溶剂,随后采用高效液相色谱二极管阵列检测法,用于从蛋黄中萃取和测定包括叶黄素和β-胡萝卜素在内的两种类胡萝卜素。该方法基于将类胡萝卜素从样品溶液微萃取到位于中空纤维内腔的萃取剂(20 μL)中,然后进行涡旋混合。采用混合溶剂(1-辛醇+1-十一醇,6:4,v:v)作为萃取剂,因为它具有合适的粘度,并且通过中空纤维与类胡萝卜素具有良好的相容性。利用涡旋混合来有效且温和地混合样品溶液,并增加分析物与中空纤维边界层之间的接触。研究并优化了影响回收率的参数。在最佳条件下,叶黄素和β-胡萝卜素的线性范围为50至1000 ng/mL,校准曲线的相关系数>0.9982,相对标准偏差(n = 5)在2.23%至3.51%之间,叶黄素和β-胡萝卜素的检测限分别为0.038和0.045 μg/mL。所提出的方法成功应用于蛋黄中类胡萝卜素的萃取和测定,相对回收率令人满意(90.2-101.8%)。