Suppr超能文献

通过股骨髁曲率半径进行骨软骨异体移植供体与受体匹配

Osteochondral Allograft Donor-Host Matching by the Femoral Condyle Radius of Curvature.

作者信息

Bernstein Derek T, O'Neill Craig A, Kim Ryan S, Jones Hugh L, Noble Philip C, Harris Joshua D, McCulloch Patrick C

机构信息

Houston Methodist Orthopedics & Sports Medicine, Houston, Texas, USA.

Institute of Orthopedic Research & Education, Houston, Texas, USA.

出版信息

Am J Sports Med. 2017 Feb;45(2):403-409. doi: 10.1177/0363546516671519. Epub 2016 Oct 29.

Abstract

BACKGROUND

Conventional osteochondral allograft (OCA) matching, requiring orthotopic, size-matched condyles, and narrow surgical time windows often prohibit timely transplantation.

HYPOTHESIS

The femoral condyle radius of curvature (RoC) is an appropriate, isolated criterion for donor-host matching in fresh OCAs, potentially enhancing matching efficiency when compared with conventional matching techniques.

STUDY DESIGN

Descriptive laboratory study.

METHODS

In part 1 of this study, 3-dimensional digital reconstructions of 14 randomly selected, cadaveric distal femoral hemicondyles were performed. Each condyle was divided into anterior, middle, and posterior zones. A virtual best-fit grid was applied to each, and each zone's sagittal- and coronal-plane RoCs were determined. Seven nonorthotopic OCA transplantations were performed based on RoC matching with 1-mm tolerance, and the preoperative and postoperative surface geometry were quantified to assess the accuracy of articular surface restoration. Of note, each donor-host pair did not match by the conventional method. In part 2 of this study, 12 cadaveric distal femora were categorized by size and digitized in the aforementioned manner. Simulated circular defects measuring 20, 25, and 30 mm in diameter were introduced into each zone. OCA matches were determined based on donor and host RoCs, and the total number of potential matches (of 71 total comparisons) was recorded as a percentage for each simulated defect. Finally, the results of RoC matching were compared with the conventional method for simulated defects in all zones of both the medial and lateral femoral condyles.

RESULTS

Part 1: The mean surface deviation after OCA transplantation was -0.09 mm, with a mean maximum protrusion at any point of 0.59 mm. Part 2: Using the RoC, 20-mm defects had a 100% chance of being matched. Defects of 25 and 30 mm had a 91% and 64% chance of being matched, respectively. Compared with the conventional method, the RoC method yielded a 3.2-fold greater match rate for lesions of the medial and lateral femoral condyles ( P = .02).

CONCLUSION

This investigation shows that femoral condyle RoCs in the sagittal and coronal planes may be useful, alternative matching criteria, expanding on current standards.

CLINICAL RELEVANCE

These matching criteria may increase the number of available matches, reduce wait times for patients, and reduce the number of wasted grafts.

摘要

背景

传统的骨软骨异体移植(OCA)匹配需要原位、尺寸匹配的髁,且手术时间窗狭窄,这常常阻碍及时移植。

假设

股骨髁的曲率半径(RoC)是新鲜OCA供体-受体匹配的一个合适的、独立的标准,与传统匹配技术相比,可能提高匹配效率。

研究设计

描述性实验室研究。

方法

在本研究的第1部分,对14个随机选择的尸体股骨远端半髁进行三维数字重建。每个髁被分为前、中、后区。对每个区域应用虚拟最佳拟合网格,并确定每个区域矢状面和冠状面的RoC。基于RoC匹配(公差为1毫米)进行了7次非原位OCA移植,并对术前和术后的表面几何形状进行量化,以评估关节面修复的准确性。值得注意的是,每对供体-受体按传统方法不匹配。在本研究的第2部分,将12个尸体股骨远端按尺寸分类,并以上述方式进行数字化处理。在每个区域引入直径为20、25和30毫米的模拟圆形缺损。根据供体和受体的RoC确定OCA匹配,并将潜在匹配总数(共71次比较)记录为每个模拟缺损的百分比。最后,将RoC匹配的结果与股骨内外侧髁所有区域模拟缺损的传统方法进行比较。

结果

第1部分:OCA移植后的平均表面偏差为-0.09毫米,任何点的平均最大突出度为0.59毫米。第2部分:使用RoC,20毫米的缺损有100%的匹配机会。25毫米和30毫米的缺损匹配机会分别为91%和64%。与传统方法相比,RoC方法使股骨内外侧髁病变的匹配率提高了3.2倍(P = 0.02)。

结论

本研究表明,矢状面和冠状面的股骨髁RoC可能是有用的替代匹配标准,是对当前标准的扩展。

临床意义

这些匹配标准可能增加可用匹配的数量,减少患者的等待时间,并减少废弃移植物的数量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验