The Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Replacement Is Not Increased by Large Articulations: A Randomized Controlled Trial.

作者信息

Howie Donald W, Holubowycz Oksana T, Callary Stuart A

机构信息

Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia.

出版信息

J Bone Joint Surg Am. 2016 Nov 2;98(21):1786-1793. doi: 10.2106/JBJS.15.01248.

Abstract

BACKGROUND

Larger articulations reduce the risk of dislocation following primary total hip arthroplasty, leading to increased use of these articulations. The wear rate of highly cross-linked polyethylene (XLPE) is low in standard-diameter articulations but remains unclear in larger articulations. The aim of this randomized controlled trial was to compare the mean wear rates of 36-mm and 28-mm metal-on-XLPE articulations between 1 and 3 years postoperatively.

METHODS

Fifty-six elderly patients undergoing primary total hip arthroplasty were randomized intraoperatively to receive either a 36-mm or 28-mm metal-on-XLPE articulation. Factors that may affect wear were controlled by study design. Wear was measured using radiostereometric analysis.

RESULTS

Mean annual proximal wear rates between 1 and 3 years were 0.00 and 0.01 mm/yr for the 36 and 28-mm articulation cohorts, respectively. No patient had a proximal wear rate of >0.1 mm/yr. Mean wear was very low in all directions, and the wear rate of 36-mm articulations was not significantly greater than that of 28-mm articulations on the basis of proximal, medial 2-dimensional, and 3-dimensional wear.

CONCLUSIONS

The wear rate of a larger 36-mm metal-on-XLPE articulation between 1 and 3 years following primary total hip arthroplasty was low and no greater than that of a 28-mm articulation. However, before a 36-mm metal-on-XLPE articulation is widely recommended, particularly in young active patients, long-term wear rates and association between wear and periprosthetic osteolysis should be determined.

LEVEL OF EVIDENCE

Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

摘要

背景

更大尺寸的关节在初次全髋关节置换术后可降低脱位风险,这使得此类关节的使用增多。在标准直径的关节中,高交联聚乙烯(XLPE)的磨损率较低,但在更大尺寸的关节中情况仍不明确。本随机对照试验的目的是比较术后1至3年36毫米和28毫米金属对XLPE关节的平均磨损率。

方法

56例接受初次全髋关节置换术的老年患者在术中随机接受36毫米或28毫米金属对XLPE关节。可能影响磨损的因素通过研究设计加以控制。采用放射立体分析测量磨损情况。

结果

1至3年期间,36毫米和28毫米关节组的年近端平均磨损率分别为0.00和0.01毫米/年。没有患者的近端磨损率>0.1毫米/年。各个方向的平均磨损都非常低,基于近端、内侧二维和三维磨损情况,36毫米关节的磨损率并不显著高于28毫米关节。

结论

初次全髋关节置换术后1至3年,更大尺寸的36毫米金属对XLPE关节的磨损率较低,且不高于28毫米关节。然而,在广泛推荐使用36毫米金属对XLPE关节之前,尤其是在年轻活跃患者中,应确定其长期磨损率以及磨损与假体周围骨溶解之间的关联。

证据水平

治疗性二级。有关证据水平的完整描述,请参阅作者须知。